Hdd Led; Overheat/Fan Fail Led; Power Fail Led - Supero AS-1010S-T User Manual

Supermicro as-1010s-t servers: user guide
Table of Contents

Advertisement

HDD LED

The HDD (IDE Hard Disk Drive) LED
connection is located on pins 13 and
14 of JF1. Attach the IDE hard drive
LED cable to display disk activity.
Refer to the table on the right for pin
defi nitions.
NIC1 LED
The NIC1 (Network Interface Control-
ler) LED connection is located on pins
11 and 12 of JF1. Attach the NIC1
LED cable to display network activity.
Refer to the table on the right for pin
defi nitions.
NIC2 LED
The NIC2 (Network Interface Control-
ler) LED connection is located on pins
9 and 10 of JF1. Attach the NIC2
LED cable to display network activity.
Refer to the table on the right for pin
defi nitions.

Overheat/Fan Fail LED

Connect an LED to the OH connection
on pins 7 and 8 of JF1 to provide ad-
vanced warning of chassis overheat-
ing. Refer to the table on the right for
pin defi nitions.

Power Fail LED

The Power Fail LED connection is lo-
cated on pins 5 and 6 of JF1. See the
table on the right for pin defi nitions.
Note: This feature is only available when using
redundant power supplies.
Chapter 5: Advanced Motherboard Setup
Pin Defi nitions (JF1)
Pin#
13
14
Pin Defi nitions (JF1)
Pin#
11
12
Pin Defi nitions (JF1)
Pin#
9
10
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin#
7
8
Power Fail LED
Pin Defi nitions (JF1)
Pin#
5
6
5-13
HDD LED
Defi nition
Vcc
HD Active
NIC1 LED
Defi nition
Vcc
NIC1 Active
NIC2 LED
Defi nition
Vcc
NIC2 Active
Defi nition
Vcc
Control
Defi nition
Vcc
Control