Servomotor (Sqm 40) - Riello DB 12 LM C10 Installation, Use And Maintenance Instructions

Light oil burner
Table of Contents

Advertisement

Available languages

Available languages

3.11 Servomotor (SQM 40)

Warnings
To avoid accidents, material or environmental
damage, observe the following instructions!
Avoid opening, modifying or forcing the servomo-
WARNING
tor.
 All interventions (assembly and installation operations,
assistance, etc.) must be carried out by qualified personnel.
 Falls and collisions can negatively affect the safety func-
tions. In this case, the servomotor must not be operated,
even if it displays no evident damage.
 Fully disconnect the burner from the mains when working
near terminals and servomotor connections.
 Condensation and exposure to water are not allowed.
 For safety reasons, the servomotor must be checked after
long periods of non-use.
20198588
Technical description of the burner
12
GB
S8907
Technical data
Mains voltage
Mains frequency
Power absorption
Motor
Drive angle
Never adjust the red cam No. 1 more than 135° to
prevent serious or irreversible damage to the me-
chanical adjustment parts.
WARNING
Protection level
Cable entry
Cable connection
Rotation direction
Rated torque (max.)
Holding torque
Operation time
Weight
Environmental conditions:
Operation
Transport and storage
230 V -15% +10%
50 / 60 Hz
7 ... 15 VA
Synchronous
Varying between 0° and 135°
Max. IP 66, with appropriate
cable entry
2 x M1/2 NPT
2
terminal board for 0.5mm
2
and 2.5mm
(max.)
Anticlockwise
10 Nm
5 Nm
45 s. at 90°
approx. 2 kg
-20....+60° C
-20...+60°C
Fig. 7
(min.)
Tab. F