NOTE: Wine Guardian unit has an internal trap. Do not double trap
piping. Failure to comply may lead to water leaks and possible wa-
ter damage to surrounding mounting area. Install drain line with a
¼ inch per linear foot (1.25 cm/linear meter) of pitch.
3. Installing Thermostat (Wired) — continued
E. Locate the Mounting Template upon the wall where
the Controller will be mounted. Using the crosses on
the template to assist in levelling the template.
G. Drill two 1/8" holes and insert anchors at the marked
locations. Anchors may not be required if securing to
a wall stud or racking system. Insert the screws into
the holes and test fit the backing plate to ensure it
mounts easily onto the two screws and slides down
onto the slotted opening freely.
H. Plug in the communication cable to the back of the
remote interface controller and seal the cable hole to
prevent false readings.
I.
Attach the Controller to the wall
J. Reconnect RJ-9 cable to side of the Wine Guardian
unit at either COM1 or COM2.
Note: For wireless installations or multiple remote
interfaces, refer to the full version manual located
at
wineguardian.com/manuals
4. Condensate Drain
A.
Wine Guardian ducted systems are supplied with 7 feet
(2 meters) of ½" (13 mm) inside dimension clear tube.
B.
Connect clear plastic tube to barbed fitting at unit and
route to nearest open floor drain, sink or condensate
pump.
5. Installing Ductwork
A.
Wine Guardian unit is supplied with one (1) supply
duct collar and (1) return duct collar as standard
equipment. Install ductwork by folding back the insula-
tion to expose the wire reinforced vinyl duct.
B.
Slip the ductwork over the end of the duct collar and
fasten using two tie wraps supplied with the kit making
sure the ductwork is tight on the duct collar.
4