Program Zones - Honeywell L5210 Series Installation And Setup Manual

Hide thumbs Also See for L5210 Series:
Table of Contents

Advertisement

Program Zones

The following system options are programmed in this section:
Option
Serial Number
Loop Number
Zone Description 1/2
Device Type
Response Type
Alarm Report
Chime
Supervision
Arm Night
Note: If applicable, preprogrammed defaults for the L5210/L7000 Control are shown on the screen unless otherwise noted.
SCREEN
Zones
5000-100-133-V0
Serial Number
Loop Number
1
Manually enter device serial number or enroll via RF transmission
Manually enter device loop number or enroll via RF transmission
Enter Zone Descriptors for the device being enrolled
Select the type of device being enrolled
Select the alarm response for the device being enrolled (refer to Zone Response Type Table)
Activate reporting option for the device being enrolled
Enable/disable chime mode for specific device being enrolled (applies to Entry/ Exit, Perimeter,
and Interior Response types only)
Select supervision for device being enrolled
Allows specific programmed motion sensors to be active when Arm Night mode is enabled and
the system is Armed in Stay mode by the User.
1. Select "Zones"
The System displays the following options:
1. New
3. Back Door
5. Motion Sensor
2. Use the down
arrow to scroll to the next page of options. Use the
the previous page.
7. – 45. New
46. – 48. New (Main) (reserved for Garage Door Zones)
49. – 64. New
140. – 147. 4 Button
148. – 155. New (Button Zones)
180. – 185. Temperature (Z-Wave Thermostat zones) (L5210 only)
180. – 187. Temperature (Z-Wave Thermostat zones) (L7000 only)
95. Fire
96. Medical
99. Police
3. Select a zone and then select "Edit" or "Add New" to program the next available zone. The
following options are displayed (dependant upon Zone Type):
Serial Number *
Zone Description 1
Device Type
Alarm Report
4. Select an option to display the next programming field.
Serial Number (This field does not apply to Temperature Zones 80-85)
When "Serial Number" has been selected "Enter Serial Number or Activate" is displayed. The
transmitter serial number and loop number can be enrolled via RF transmission OR manually.
Enroll via RF Learning To enroll the device using RF Learning mode three transmissions
(open/close) of the device will be required. The initial transmission activates the RF Learning
mode and the system will emit a single beep. A second transmission enrolls the serial number
and the system beeps two times and displays "Activate Sensor Again To Confirm". A third
transmission will confirm the serial number. The system beeps two times and returns to the
Zone programming Screen.
Enroll Manually
Enter the 7-digit serial number printed on the transmitter using the displayed keypad and
select "Done". The system beeps one time and returns to the Zone programming Screen.
Loop Number (This field does not apply to Temperature Zones 80-85)
Select "Loop Number" to toggle between 1, 2, 3 and 4. Enter Save.
LYNX Touch Installation and Setup Guide
Programming the Control
Function
ACTION
2. Front Door
4.Window
6.New
Loop Number *
Zone Description 2
Response Type
Chime
Supervision
- 35 -
arrow to return to
* This field does not apply to
Hardwire Zone 1 or
Temperature Zones 80-85.

Advertisement

Table of Contents
loading

This manual is also suitable for:

L7000 series

Table of Contents