Error Displays Of The Operating Mode Leds; Error Displays Of The Signal Quality Display - Leuze electronic DDLS 538 Series Original Operating Instructions

Optical data transmission for ethercat
Table of Contents

Advertisement

Diagnostics and troubleshooting
8.3

Error displays of the operating mode LEDs

Tab. 8.8:
LLC LED displays - Causes and measures
LED
Color
LLC
Red
8.4
Error displays of the SIGNAL QUALITY display
Tab. 8.9:
SIGNAL QUALITY displays - causes and measures
LED
Color
SIGNAL
---
QUALITY
Leuze electronic GmbH + Co. KG
State
possible causes
Continuous
• Optical window soiled
light
• Travel tolerances greater
than the transmission
beam spread
• Mounting/alignment insuffi-
cient
• Range exceeded
• Environmental influences
(snow, rain, fog)
• Transmitter of the first de-
vice deactivated
• Transmitter of the second
device deactivated
State
possible causes
OFF
MAS EtherCAT configuration is ac-
tivated on both devices.
MAS EtherCAT configuration is
deactivated on both devices.
Measures
• Clean optical window.
• Eliminate the possibility of environ-
mental influences such as snow, rain,
fog.
• Check the mounting/alignment of the
devices:
Screw fitting of the devices
Alignment
Spring tension on the alignment
screws
• End deactivation of the transmitters.
DDLS 538 ...
Measures
Check MAS EtherCAT configuration
(see chapter 7.2 "MAS EtherCAT
configuration of the DDLS 538 ..."):
• Device installed on master side:
activate MAS
• Device installed on slave side:
deactivate MAS
65

Advertisement

Table of Contents
loading

Table of Contents