Indicators In The Optics Area - Leuze electronic DDLS 538 Series Original Operating Instructions

Optical data transmission for ethercat
Table of Contents

Advertisement

Device description
3.3.2

Indicators in the optics area

For simple, quick diagnosis, the device is equipped with a STATUS LED in the optics area.
The STATUS LED enables a quick summary diagnosis of the operating state of the device.
• The STATUS LED summarizes the displays of the individual LEDs of the control panel in a single indi-
cator.
• The STATUS LED illuminates very brightly and can also be seen from a relatively long distance.
1
1
STATUS LED
Fig. 3.6:
STATUS LED in the optics area
Tab. 3.4:
Meaning of the STATUS LED display
LED
Color
STATUS
Green
LED
Green
---
Leuze electronic GmbH + Co. KG
State
Description
Continuous light
Not a warning or error message.
Flashing
There is/are warning message(s) (see chapter 8.2 "Error dis-
plays and STATUS LED for remote diagnosis"):
• SIGNAL QUALITY indicator without green LED in operating
modes AUT (Automatic), MAN (Manual), ADJ (Adjust)
• Temperature, warning or error (TMP)
• Laser pre-failure (LSR)
• Link Loss Counter has triggered (LLC)
Data transmission is active.
OFF
• No supply voltage.
• SIGNAL QUALITY indicator shows only red LEDs.
• The LINK and LINK/ACT LEDs are off.
• The transmitter is deactivated (see chapter 8.2 "Error dis-
plays and STATUS LED for remote diagnosis").
• MAS EtherCAT configuration is activated on both devices
or MAS EtherCAT configuration is deactivated on both de-
vices.
DDLS 538 ...