Device description
Operating state indicator
The PWR, TMP, LSR, MAS, OLK, ERL and LINK LEDs indicate the operating state of the device.
1
1
PWR – Supply voltage (Power)
2
TMP – Temperature warning/error
3
LSR – Laser prefailure message
4
MAS – Master-side installation of the DDLS 538 ...
5
OLK – Optical link
6
ERL – Error Link
7
LINK – M12 cable-connected link
Fig. 3.4:
Operating state LEDs in the control panel
Tab. 3.2:
Meaning of the operating state indicators
LED
Color
PWR
---
Green
Green
Red
Red
Leuze electronic GmbH + Co. KG
2
3
4
State
OFF
Flashing
Continuous light
Flashing
Continuous light
5
6
7
Description
No supply voltage (see chapter 8.1 "Error displays of the op-
erating state LEDs")
Device is being initialized
• Supply voltage connected
• Initialization running
• No data sent or received
Data transmission path ready
• Initialization finished
Warning set (see chapter 8.1 "Error displays of the operating
state LEDs")
• No green and orange LEDs in SIGNAL QUALITY indica-
tor
• The optical link is interrupted.
• The laser diode of the transmitter is defective.
Device error (see chapter 8.1 "Error displays of the operating
state LEDs"
• The function of the device is limited.
The displays of the other operating state LEDs may pro-
vide information on the cause of the error.
DDLS 538 ...
17