Vogt TUBE-ICE 03TB Service Manual page 93

Table of Contents

Advertisement

03TA Service Manual
Circulating Water Pump Motor. The motor bearings are prelubricated and sealed. They require
no further lubrication. The pump should operate with the water level above the impeller housing.
The pump is equipped with a mechanical seal that is self-adjusting and requires no lubrication.
However, the pump should not be operated unless circulating water. The pump manufacturer
recommends that a mechanical seal be kept as a spare. When ordering a seal, specify pump size,
type, serial number, and manufacturer's name as indicated on the nameplate.
Pump Discharge (1 1/2" FPT)
Seal Kit Part #: 12A4080S12
Cutter Gear Reducer. The oil level for the gear reducer should be checked if there is evidence of a
leak. It should be level with the plugged opening in the side of the gear housing. Use Mobile 600W
cylinder oil or equal. Change oil once a year.
The motor bearings are prelubricated and require no further lubrication. For additional information,
refer to manufacturer's instructions.
Gear Reducer (10:1)
Replacement food grade oil:
Part #: 12A4030R12
Part #: 19T3020C01
Texaco Cygnus 220
Oil Capacity: 8 ounces
4/2/14
Pump Suction (2" FPT)
Oil Level Plug
Note: Ventless gear reducer used after August 2010
Pump Part #: 12A4020G01
FIGURE 9-10
Water Pump
Vent Plug
Drain Plug
FIGURE 9-11
Gear Reducer
9-11
SERVICE OPERATIONS
Vent Plug
Gear Reducer (5:1)
Crushed Ice Only
Part #: 12A4030R14

Advertisement

Table of Contents
loading

This manual is also suitable for:

He60P112f

Table of Contents