Wiring And Electrical Connection - Vogt TUBE-ICE 03TB Service Manual

Table of Contents

Advertisement

3-8
INSTALLING YOUR TUBE-ICE

Wiring and Electrical Connection

Only service personnel experienced in refrigeration and qualified to work with high voltage
electrical equipment should be allowed to install or work on the Tube-Ice
Refer to TABLE 3-2 below to properly size wiring connections. A fused disconnect must be
provided near the Tube-Ice
block (PDB) for operation of the Tube-Ice
motor and water pump is required (see following section). Also, if one leg of the 3 phase power is
higher or lower ("Wild"), then it should be connected to terminal #L2. Connect the "Ground" wire
to the "Ground" lug provided.
MAIN MACHINE POWER
Incoming power to be connected to
Power Distribution Block (PDB)
AIR COOLED CONDENSER CONNTECTIONS
Power for Condenser control circuit (11 & 22)
Standard Voltages
208/230, 3ph, 60 Hz
460, 3ph, 60 Hz
200, 3ph, 50 Hz
400, 3ph, 50 Hz
4/2/14
®
MACHINE
!
WARNING
!
WARNING
®
machine. Connect 3 phase power, L1, L2, L3 to the power distribution
®
machine and its controls. Rotation checking of cutter
FIGURE 3-6
Control Panel Power Connections
Water Cooled
F.L.A.
Min.
Ampacity
48.3
58.6
23.7
28.7
50.9
61.8
24.2
30.4
TABLE 3-2
Electrical Specifications
!
!
Max. Fuse
F.L.A.
100
54.3
50
26.4
110
57.5
55
27.2
03TA Service Manual
®
machine.
AUX CONNECTIONS
Cutter Motor, Pump Motor &
Compressor Interlocks
AIR COOLED CONDENSER
CONNTECTIONS
Power for Fan Motors (B7, B8 & B9)
Air Cooled
Min.
Max. Fuse
Ampacity
64.6
110
31.4
55
68.4
115
32.2
55