An oil pump should be used to force any oil that may be required into the system. Oil may be added
to the compressor through the low pressure test connection adjacent to the high/low pressure switch
or through the compressor suction service valve. The compressor suction service valve should be
"backseated" to shut off pressure to the gauge port when connecting the oil pump. Air should be
purged from the oil pump discharge line by forcing some oil through the line before tightening the
charging connection.
Cutter Gear Reducer. The oil level for the gear reducer should be checked if there is evidence of a
leak. It should be level with the plugged opening in the side of the gear housing. Use Mobile 600W
cylinder oil or equal. Change oil once a year.
Gear Reducer (10:1)
Part #: 12A4030R12
Replacement food grade oil:
Part #: 19T3020C01
Texaco Cygnus 220
Oil Capacity: 8 ounces
3/31/14
Compressor
3DE3R & 3DEHR
3DP3R & 3DPHR
TABLE 7-3
Compressor Oil Capacity
Oil Level Plug
Note: Ventless gear reducer used after August 2010
FIGURE 7-2
Gear Reducer
HP
Oil Charge (oz)
6.5
125
7.5
125
Vent Plug