9. Troubleshooting

If you cannot connect to the router from your PC, your network card may be configured
in such a way that it is not possible to connect to the router. Take one or more of the
following steps in order to solve the problem:
• Make sure your PC's network card is configured to obtain the IP address form the
DHCP server (by default the DHCP server is running in the router).
• Connect the router to the PC via Switch.
• Connect the router to the PC, start the router first and then start the PC after the
router's initialization.

9.1 FAQ

Ethernet connection fails or is not establishing.
• It is possible to turn auto negotiation off and set a rate and duplex manually on the
Ethernet interface of the router. Available on "LAN Configuration" page in the router.
Mobile WAN connection fails.
• Check the signal power ("Mobile WAN status" page). If the signal power is weak,
you will have to use a better antenna. If the neighbouring cells have a similar signal
strength, you will need to use a directional antenna. For proper operation, the signal
levels have to be good.
• Try to enable automatic ping from the router, which will check the connection when
there are no data running and in the case of a failed ping, restart the connection.
This can be done on the "Mobile WAN Configuration" page in the router in the
"Check connection" section. "Enable + bind" option is to ensure the ping goes
always through Mobile WAN network interface.
Mobile WAN connection cannot be established.
• Check the "Mobile WAN Configuration" – APN, name, password and IP address (all
can be blank).
• Try to enter the SIM card PIN – verify that the SIM card has the PIN code entered.
Available on "Unlock SIM Card" page in the "Administration" section.
• In a private APN it is not recommended to get the DNS settings from operator (on
"Mobile WAN" page)
• Go to "System Log" page in "Status" section and observe where the error occurs.