Printed Image Trouble
When the following printed image trouble occurs, implement appropriate procedures.
Symptom
Printed images are totally
too light.
Printed images are too
dark even though the
background of the
scanned original is white.
Black dots appear on the
white background when
white original is scanned.
Printed images are fuzzy.
Checkpoints
Is the paper damp?
Have you changed the density?
Is the toner distributed evenly within
the toner container?
Is EcoPrint mode enabled?
Have you changed the density?
Is the device used in an environment
with high humidity or where the
temperature or humidity changes
suddenly?
Corrective Actions
Replace the paper with new paper.
Select appropriate density level.
Shake the toner container from side
to side several times.
Disable EcoPrint mode.
Make sure the paper type setting is
correct for the paper being used.
Select the [Menu] > Adjust/
Maint. > Service Setting >
Drum > [OK] > [OK].
Select appropriate density level.
Select the [Menu] > Adjust/
Maint. > Service Setting >
Drum > [OK] > [OK].
Select the [Menu] > Adjust/
Maint. > Service Setting > MC
> [OK] > [OK] and increase the
adjustment value. Increase the
adjustment value 1 level at a time
from the current value. If there is no
improvement after the value is
increased by 1 level, increase by 1
level again. If there is still no
improvement, return the setting to
the original value.
Select the [Menu] > Adjust/
Maint. > Service Setting >
Drum2, load A4 paper in the multi
purpose tray, and select [OK] >
[OK]. (Except PG L2545)
Use in an environment that has
suitable humidity.
Select the [Menu] > Adjust/
Maint. > Service Setting >
Drum > [OK] > [OK].
8-4
Troubleshooting
Reference
Page
page 2-38
page 4-54
page 7-3
page 4-53
page 4-39
page 4-54