9. Relationship between Upstream Piping and Peak Pressure
Relationship between Upstream side Tube and Peak Pressure
<Measurement conditions>
Upstream side: Tube T1613, TU1610, and TU1208. The length of the tube is cut so that the pipe volume is 100cc and 50cc.
Downstream side: Standard nozzle (50mm)
Supply pressure: 0.3 MPa, 0.5MPa
Measurement point: 10mm and 50mm from the opening of the nozzle.
Relation between Peak Pressure and
Upstream side tube
(supply pressure 0.5MPa, volume 50cc)
TU1208 tube
T1613 tube
0.25
0.2
0.15
0.1
0.05
0
10mm
Distance from the nozzle
Relation between Peak Pressure and
Upstream side tube
(supply pressure 0.3MPa, volume 50cc)
TU1208 tube
T1613 tube
0.25
0.2
0.15
0.1
0.05
0
10mm
Relationship between Upstream side Tube, Downstream side nozzle and Peak Pressure
<Measurement conditions>
Upstream side: Tube T1613, TU1610, and TU1208. The length of the tube is cut so that the pipe volume is 100cc.
Downstream side: Standard nozzle (50,150,300mm)
Supply pressure: 0.5 MPa
Measurement point: 10mm from the opening of the nozzle.
Relation between Upstream side Tube,
Downstream side Nozzle and Peak Pressure
(supply pressure 0.5MPa, , volume 100cc)
TU1208 tube
0.25
0.2
0.15
0.1
0.05
0
50mm
Downstream side nozzle length
TU1610 tube
Normal air blow
50mm
TU1610 tube
Normal air blow
50mm
TU1610 tube
T1613 tube
150mm
300mm
Relation between Peak Pressure and
Upstream side tube
(supply pressure 0.5MPa, volume 100cc)
TU1208 tube
T1613 tube
0.25
0.2
0.15
0.1
0.05
0
10mm
Distance from the nozzle
Relation between Peak Pressure and
Upstream side tube
(supply pressure 0.3MPa, volume 100cc)
TU1208 tube
T1613 tube
0.25
0.2
0.15
0.1
0.05
0
10mm
Distance from the nozzle
10
TU1610 tube
Normal air blow
50mm
TU1610 tube
Normal air blow
50mm
* In SMC test conditions.