Battery Connection - MPP Solar PIP3024GEW User Manual

Inverter / charger
Table of Contents

Advertisement

Install the unit by screwing two screws. It's recommended to use M4 or M5 screws.

Battery Connection

This model can be operated without battery connection. Connect to battery if necessary.
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current
protector or disconnect device between battery and inverter. It may not be requested to have a disconnect
device in some applications, however, it's still requested to have over-current protection installed. Please refer
to typical amperage in below table as required fuse or breaker size.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery
connection. To reduce risk of injury, please use the proper recommended cable as below.
Recommended battery cable size:
Model
PIP3024GEW
PIP5048GEW
Please follow below steps to implement battery connection:
1. For PIP5048GEW model, remove insulation sleeve 18 mm for positive and negative conductors. Suggest to
put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
For PIP3024GEW model, refer to recommended battery spec table to purchase separately two ring
terminals and battery wires. Assemble two ring terminals with battery wires based on recommended battery
cable and terminal size as grounding cable. Recommended dimensions for ring terminal is D (8.4 mm) and
L (39.2 mm).
2. This step is only for PIP5048GEW model. Fix strain relief plate to the inverter with supplied screws as
Wire Size
Cable (mm
1 x 2AWG
35
5
2
Torque value(max)
)
2 Nm