Input Power Connections; Control Supply Connector; Figure 2-1: Control Supply Connections; Table 2-1: Control Supply Wiring Specifications - Advantech Automation1 iXC4e Hardware Manual

Pwm high-performance digital drives
Table of Contents

Advertisement

2.1. Input Power Connections

2.1. Input Power Connections
The iXC4e/XC4e has two AC input power connectors. One connector is for control power and the other
connector is for motor power. For a full list of electrical specifications, refer to
to Section 2.10.
for a System Interconnection Drawing.

2.1.1. Control Supply Connector

The Control Supply input supplies power to the communications and logic circuitry of the iXC4e/XC4e .
The L input is connected to an internal fuse. Refer to
number. The N input is not connected to an internal fuse. An external fuse will be required if N is not
connected to Neutral.
The Control Supply contains an internal filter but you could be required to add an external filter for CE
compliance. Install the external filter as close as possible to the drive. Use a Schaffner FN2080 filter, an
Aerotech UFM-ST noise filter module, or equivalent device.
IMPORTANT: Refer to local electrical safety requirements to correctly size external system
wires.
Table 2-1:
Control Supply Wiring Specifications
Pin
Description
L
Line (L): 100-240 VAC Control Power Input
Neutral (N) or 100-240 VAC Control Power Input with external
N
fuse
Protective Ground
Table 2-2:
Mating Connector Part Numbers for the Control Supply Connector
Type
3-Pin Terminal Block
30
Table 5-4
Figure 2-1:
Control Supply Connections
Aerotech
Third Party
P/N
P/N
ECK00213
Phoenix 1754465
iXC4e/XC4e Hardware Manual
Section
1.1. Refer
for the internal fuse value and part
Recommended Wire Size
2
0.8 mm
2
0.8 mm
2
0.8 mm
Screw
Wire Size:
Torque: N·m
mm
0.5 - 0.6
3.3 - 0.516 [12-30]
www.aerotech.com
(#18 AWG)
(#18 AWG)
(#18 AWG)
2
[AWG]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Automation1 xc4e

Table of Contents