HIKVISION DS-7608NI-L1/W User Manual page 79

Table of Contents

Advertisement

Note
This function is only available for certain models.
4) Click Draw Area and draw a quadrilateral in the preview window by specifying four vertexes of
the detection region.
6. Set the arming schedule. Refer to Configure Arming Schedule for details.
7. Set the linkage actions. Refer to Configure Alarm Linkage Action for details.
8. Click Apply.
Temperature Screening
After specified thermography cameras are connected, the device can display temperature
measurement results, and notify you with audio alert when normal or abnormal temperature is
detected.
Before You Start
Ensure your thermography camera supports this function, and it is properly configured.
Steps
1. Go to Configuration → Event → Smart Event .
2. Select the optical channel of thermography camera.
3. Click Face Detection.
4. Set Alarm Temperature. When the detected temperature exceeds the alarm temperature, the
device will trigger an alarm.
5. Set Sensitivity.
Sensitivity
It refers to face detection sensitivity.
6. Set the arming schedule. Refer to Configure Arming Schedule for details.
7. Set the linkage actions. Refer to Configure Alarm Linkage Action for details.
8. Click Apply.
What to do next
You can click
in live view to view detection results. Normal temperature will be displayed in
green color, abnormal temperature will be displayed in red color.
You can click Search at the top to search related files.
Thermal Camera Detection
The device supports the event detection modes of thermal network cameras: fire detection,
temperature detection, etc. You can configure the arming schedule and linkage actions of the
selected event.
Before You Start
Add a thermal network camera to your device and make sure the camera is activated.