Alarm; Alarm Connections; Connect On Alarm; Number Of Destination Ip Address - Bosch TINYON IP 2000 WI Software Manual

Camera browser interface
Table of Contents

Advertisement

Camera Browser
Interface
10

Alarm

10.1

Alarm Connections

In the event of an alarm, the unit can automatically connect to a
pre-defined IP address. The unit can contact up to ten IP
addresses in the order listed until a connection is made.
10.1.1

Connect on alarm

Select On so that the unit automatically connects to a pre-
defined IP address in the event of an alarm.
Select Follows input 1 so that the unit maintains the connection
for as long as an alarm exists on alarm input 1.
10.1.2

Number of destination IP address

Specify the numbers of the IP addresses to be contacted in the
event of an alarm. The unit contacts the remote locations one
after the other in the numbered sequence until a connection is
made.
10.1.3

Destination IP address

For each number, enter the corresponding IP address for the
desired remote station.
10.1.4

Destination password

If the remote station is password protected, enter the password
here.
Only ten passwords can be defined here. Define a general
password if more than ten connections are required, for
example, when connections are initiated by a controlling system
such as Bosch Video Client or Bosch Video Management System.
The unit connects to all remote stations protected by the same
general password. To define a general password:
1.
2.
3.
Bosch Security Systems
Select 10 in the Number of destination IP address list box.
Enter 0.0.0.0 in the Destination IP address field.
Enter the password in the Destination password field.
Alarm | en
2015.01 | v1.59x | AM18-Q0676
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tinyon ip 2000 pir

Table of Contents