Choice Of Location - Fronius Eco Installation Instructions Manual

Table of Contents

Advertisement

Choice of loca-
tion
IP 66
NH
The inverter is suitable for indoor installation.
The inverter is suitable for outdoor installation.
Because of its IP 66 protection class, the inverter is resistant to
water jets from any direction and can also be used in damp en-
vironments.
In order to minimise the heating up of the inverter, do not ex-
pose it to direct insolation. Install the inverter in a protected
location, e.g. in the vicinity of the solar modules or beneath the
eaves.
Fronius Symo:
U
at an altitude of:
DCmax
0 to 2000 m = 1000 V
2001 to 2500 m = 950 V
2501 to 3000 m = 900 V
3001 to 3400 m = 850 V
IMPORTANT! The inverter must not be installed or used at alti-
tudes above 3400 m.
Fronius Eco:
U
at an altitude of:
DCmax
0 to 2000 m = 1000 V
2001 to 2500 m = 950 V
IMPORTANT! The inverter must not be installed or used at alti-
tudes above 2500 m.
Do not install the inverter in:
3
-
Areas where ammonia, corrosive vapours, acids or salts are
present
(e.g. fertiliser stores, ventilation openings from cattle sheds,
chemical plants, tanneries, etc.)
During certain operating phases the inverter may produce a
slight noise. For this reason it should not be installed in an occu-
pied living area.
Do not install the inverter in:
-
Places where there is an increased risk of damage from farm
animals (horses, cattle, sheep, pigs, etc.)
-
Stables or adjoining areas
-
Storage areas for hay, straw, chaff, animal feed, fertilisers,
etc.
7