Setting Full and Empty calibration manually

We do not recommend it but you can set the Full and Empty calibration values
manually to save time if you always cut/extend the sensor equal to the same length
and install them in 'similar' tanks.
ATTENTION!!!
margin of error of the sensor! We do not recommend using this option!
To do so, open engineer menu and click on Full/Empty manual setting in opened
menu set values of the FULL and EMPTY tank and click OK.
Setting calibration values manually will likely increase the
Fig. 61.1 Setting Full and Empty values manually