E-016
Overload
E-017
Power off when
running
Erase parameter
E-018
error
Motor code
E-031
error
Initialization
E-032
error
►►Debug steps
b)
Please check the products before power on, make sure the devices are not
significant damage.
Connect the cables correctly. Connect U, V, W one-to-one, don't cross them.
c)
d)
Power on, panel display: bb;
e)
Enter F2-00,set the correct motor code.
f)
After power on again,proceed to current Offset Auto-Adjustment,please refer to
auxiliary run mode;
g)
Set F1-01=1, check if the motor can work normally. If yes, enter F1-00. If not,
check the cables.
h)
Enter F1-00 and proceed to jog test-running, if work normally, connect to motor.
i)
Before start the devices, set the parameters of servo according to actual
application, and adjust in real-time.
56
Run overload for long time
Bus voltage is too low when
running
Voltage is too low when
power on, cannot erase the
parameter
Motor code cannot match to
drive type
System chip is damaged
Reduce the overload running
time, change a motor with larger
rated power
Re-power on after the bus
voltage is normal
Check the power supply and
re-power on
Set the motor code in F2-00
again
Contact XINJE or an authorized
distributor