Installing The Switch - Cisco Nexus 92300YC Hardware Installation Manual

Table of Contents

Advertisement

Installing the Switch

• Model and serial number of the damaged unit
• Description of damage
• Effect of damage on the installation
Step 3
Check to be sure that each of the power supply and the fan tray modules have the expected direction of airflow as follows:
• Port-side intake airflow modules
◦ Red (fan modules and power supplies)
• Port-side exhaust airflow modules
◦ Blue (fan modules and power supplies)
• Dual-direction airflow power-supply modules
◦ White (see the color of the fan modules to determine the airflow direction used)
Note
All power supplies and fan modules must have the same direction of
airflow.

Installing the Switch

To install the switch, you must attach front and rear mounting brackets to the switch, install slider rails on the
rear of the rack, slide the switch onto the slider rails, and secure the switch to the front of the rack. Typically,
the front of the rack is the side easiest to access for maintenance.
You must supply the eight 10-32 or 12-24 screws required to mount the slider rails and switch to the rack.
Note
Before You Begin
• You have inspected the switch shipment to ensure that you have everything ordered.
• Make sure that the switch rack-mount kit includes the following parts:
Cisco Nexus 92300YC NX-OS Mode Hardware Installation Guide
14
◦ Front rack-mount brackets (2)
◦ Rear rack-mount brackets (2)
◦ Slider rails (2)
◦ M4 x 0.7 x 8-mm Phillips countersink screws (12)
Installing the Switch Chassis