Sony CDP-XE530 Service Manual page 11

Hide thumbs Also See for CDP-XE530:
Table of Contents

Advertisement

1 track jump waveform
0V
level : 1.3
E-F Balance Check (With general remote commander)
BD board
TP (TE)
TP (VC)
Procedure :
1.
Connect the test point JW613 (ADJ) on MAIN board to the
ground with a lead wire on main board.
2.
Connect oscilloscpe to test point TP (TE) on BD board.
3.
Turn the Power switch on to set the ADJ mode.
4.
Put disc (YEDS-18) in to play the number five track.
Press the 4 button. (The tracking servo and the sledding servo
5.
are turned OFF.)
6.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse waveform
0V
Press the 9 button. (The tracking servo and sledding servo
7.
are turned ON.) Confirm the C (DC voltage) is almost equal to
the A (DC voltage) is step 6.
Traverse waveform
0V
Tracking servo
Sledding servo
OFF
8.
Disconnect the lead wire of JW613 (ADJ) connected in step 1.
Center of the waveform
B
A (DC voltage)
+ 0.7
Vp-p
symmetry
– 0.6
oscilloscope
Center of the waveform
B
A (DC voltage)
level : 1.3 ± 0.6 Vp-p
C (DC
voltage)
Tracking servo
Sledding servo
ON
— 11 —
Adjustment Location :
[ MAIN BOARD ] – Component Side –
CN621
JW613 (ADJ)
JW617 (AFADJ)
[ BD BOARD ] – Side A –
TP
(R151)
TP(FE)
TP(TE)
TP(FEI)
TP(RF)
TP(VC)
TP(IOP)
CN102
IC101

Advertisement

Table of Contents
loading

Table of Contents