Page 1
Model Document Vallox 101 MC R D4686 Vallox 101 MC L Valid from 02.05.2022 Type C3740 Updated 16.05.2022 Manual Ventilation unit...
Page 2
Vallox ProControl panel (optional) Vallox X-Line PTXPA MC (ordered separately) (optional) Vallox Delico PTD EC control hood, Vallox X-Line PTXP MC control hood, or Vallox X-Line PTXPA MC control hood (ordered separately) Ceiling bushing for electric wires WARNING! The unit is not intended for use by children under 8 or by persons with reduced sensory, physical or mental capabilities, or whose lack of knowledge and experience do not ensure safe operation of the unit. ...
FAN SPEED ADJUSTMENT The fan speed of the Vallox ventilation unit is adjusted using a four-step control. The available speed options of the control switch are 1, 2, 3, and 4: Away mode. The ventilation efficiency can be temporarily reduced when the apartment is unoccupied.
The maintenance reminder will be set off automatically when the door of the ventilation unit is opened or the power is turned off. The maintenance reminder can also be set off manually. Vallox Delico PTD EC control hood: The Vallox Simple Control panel, and the Vallox X-Line PTXP MC and PTXPA MC control hoods, •...
BEFORE BEGINNING MAINTENANCE WORK The R model is shown in the figures. When you open the door of Vallox 101 MC, the safety In the L model, the parts are mirrored. switch (S) cuts the power. Despite this, disconnect the power supply plug anyway.
Page 6
To clean the fan: 1. Disconnect the ventilation unit from the mains electricity supply. 2. Open the door of the Vallox ventilation unit by undoing the finger screws. 3. Lift the door off. CAUTION! The door is heavy.
Page 8
Air flow measurement points TECHNICAL SPECIFICATIONS Nimike Product number Measurement points after the outlet collar. The fan curves Vallox 101 MC R 4102638 indicate the total pressure accounted for by duct losses. Vallox 101 MC L 4102629 Air volumes Supply air...
Page 11
3 and 5 from the MC unit’s control panel connector EXTERNAL ELECTRICAL CONNECTION with the Vallox Simple Control panel / Vallox PTXP MC, Vallox PTXPA MC cooker hood Control signal S Internal connection 11.2 VDC / +...
Page 12
EXTERNAL ELECTRICAL CONNECTION with Vallox ProControl panel Wiring between the control panel and the ventilation unit, NOMAK 2x2x0.5+0.5 Ventilation unit cable Control panel connector leave disconnected S/DI2 Cable types specified in the drawing are indicative The phase of 24 VAC feed is connected...
The top surface of the side panel of the unit can be installed against the finished ceiling surface. Vallox 101 MC must be installed in a location where the When the wall mounting plate is used, it must be temperature remains above +10 °C. When the unit is...
Page 14
Ceiling mounting by using a ceiling The ceiling mounting plate is fastened to the M8 thread mounting plate (optional) bars with the mounting supplies delivered with the The unit can be equipped with an optional ceiling mounting plate. NOTE! The end of the thread bars must mounting plate.
Page 15
Installation of the Vallox Silent Klick siphon on the wall Installation of the Vallox Silent If the Vallox Silent Klick siphon does not fit into the unit Klick siphon on the wall. directly, the elbow can be installed at the bottom, and The elbow underneath the the siphon can be installed on the wall.