Parameters Recommended To Be Set By The User - Mitsubishi FR-E500 Series Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR-E500 Series:
Table of Contents

Advertisement

Purpose of Use
Display of speed, etc.
Clearing of inverter's actual operation
time
Function write prevention
Reverse rotation prevention
Parameter grouping
Current detection
Motor stall prevention
Input terminal (DeviceNet input)
function assignment
Output terminal (DeviceNet output)
function assignment
Increased cooling fan life
Motor protection from overheat
Automatic restart operation at alarm
stop
Setting of ground fault overcurrent
protection
Inverter reset selection

4.1.3 Parameters recommended to be set by the user

We recommend the following parameters to be set by the user.
Set them according to the operation specifications, load, etc.
Parameter
Number
1
Maximum frequency
2
Minimum frequency
7
Acceleration time
8
Deceleration time
Electronic thermal O/L
9
relay
14
Load pattern selection
71
Applied motor
Pr. 37, Pr. 52
Pr. 171
Pr. 77
Pr. 78
Pr. 160, Pr. 173 to Pr. 176
Pr. 150 to Pr. 153, Pr. 190 to Pr. 192
Pr. 22, Pr. 23, Pr. 66, Pr. 156
Pr. 180 to Pr. 183
Pr. 190 to Pr. 192
Pr. 244
Pr. 9, Pr. 71
Pr. 65, Pr. 67, Pr. 68, Pr. 69
Pr. 249
Pr. 75
Name
Used to set the maximum and minimum output
frequencies.
Used to set the acceleration and deceleration
times.
Used to set the current of the electronic
overcurrent protection to protect the motor from
overheat.
Used to select the optimum output characteristics
which
characteristics.
Used to set the thermal characteristics of the
electronic overcurrent protection according to the
motor used.
61
Get other manuals https://www.bkmanuals.com
Parameter Numbers
Parameter numbers which must be set
Application
match
the
application
PARAMETERS
and
load