Mitsubishi FR-E500 Series Instruction Manual page 191

Transistorized inverter
Hide thumbs Also See for FR-E500 Series:
Table of Contents

Advertisement

8. Class 0x66 - E500 Extended Object 1
(1) Class 0x66 Attributes - Instance 0
Note: Not applicable to the FR-E500KND.
(2) Class 0x66 Services
Note: Not applicable to the FR-E500KND.
(3) Class 0x66 Instance Attributes Instance 1
No.
Access
10
Get/Set
Pr. 0
11
Get/Set
Pr. 1
12
Get/Set
Pr. 2
13
Get/Set
Pr. 3
14
Get/Set
Pr. 4
15
Get/Set
Pr. 5
16
Get/Set
Pr. 6
17
Get/Set
Pr. 7
18
Get/Set
Pr. 8
19
Get/Set
Pr. 9
20
Get/Set
Pr. 10 DC Injection Brake Operation Frequency
21
Get/Set
Pr. 11 DC Injection Brake Operation Time
22
Get/Set
Pr. 12 DC Injection Brake Voltage
23
Get/Set
Pr. 13 Starting Frequency
24
Get/Set
Pr. 14 Applied Load Selection
28
Get/Set
Pr. 18 High Speed Maximum Frequency Limit
29
Get/Set
Pr. 19 Base Frequency Voltage
30
Get/Set
Pr. 20 Acceleration/Deceleration Reference Frequency
31
Get/Set
Pr. 21 Acceleration/Deceleration Time Increments (Note 4) 0
32
Get/Set
Pr. 22 Stall Prevention Operation Level
Pr. 23 Stall Prevention Operation Level at Double
33
Get/Set
34
Get/Set
Pr. 24 Multi-Speed Setting (Speed 4)
35
Get/Set
Pr. 25 Multi-Speed Setting (Speed 5)
36
Get/Set
Pr. 26 Multi-Speed Setting (Speed 6)
37
Get/Set
Pr. 27 Multi-Speed Setting (Speed 7)
Parameters (Pr. 0 = No.10)
Attribute
Torque Boost
Maximum Frequency
Minimum Frequency
Base Frequency
Multi Speed (high speed)
Multi Speed (middle speed)
Multi Speed (low speed)
Acceleration Time
Deceleration Time
Electronic Thermal O/L Relay
Speed
173
Get other manuals https://www.bkmanuals.com
Default Setting
(Note 2)
(Note 2)
0.00Hz
60.00Hz
60.00Hz
30.00Hz
10.00Hz
(Note 2)
(Note 2)
(Note 2)
3.00Hz
0.5s
6.0% (Note 2)
0.50Hz
0
(Note 2)
(Note 3)
60.00Hz
150.0%
(Note 3)
(Note 3)
(Note 3)
(Note 3)
(Note 3)

Advertisement

Table of Contents
loading

Table of Contents