STB-3500 Cabling Connections (Cont.)
Connect the STB to the Display Panel
This procedure only describes the essential STB/display panel connections. See Reference section,
"STB-3500 Jack Panels," for further information on the additional jack panel ports and connectors.
1. Turn ON the display panel.
2. Refer to the STB-3500 Cabling diagram on page 9, and complete the following connections:
a) Make the appropriate Television/Display Control connection between the STB-3500 and the
display panel.  (See also * on following page.)
• For LG Hospitality TVs: Use the MPI/MTI cable provided to connect MPI/MTI TELEVISION
CONTROL on the STB-3500 front jack panel to the MPI port on the rear jack panel of the
display.
• For LG Public Display TVs or LG Commercial Monitors: Use the TLM cable provided to
connect RS-232C TELEVISION CONTROL on the STB-3500 rear jack panel to the DB9
RS-232 CONTROL connector on the rear jack panel of the display.
• For commercial non-LG TVs: Use the MPI/MTI cable provided to connect MPI/MTI
TELEVISION CONTROL on the STB-3500 front jack panel to the MTI (typically labeled
"DATA") port on the rear jack panel of the display.
b) Use the HDMI cable provided to connect HDMI OUT on the STB-3500 rear jack panel to the
HDMI1 input connector on the rear jack panel of the display.    ( See also ** on following page.)
c) For RF delivered content, connect a 75 ohm coaxial wire from the Antenna/CATV wall jack to
ANTENNA/CABLE IN on the STB-3500 rear jack panel. For IP delivered content, connect an
RJ-45 Ethernet (CAT5) cable from the institution's network to the LAN port on the STB-3500
rear jack panel.
d) Insert the DC power plug of the AC/DC power adapter provided into the POWER connector
on the rear jack panel of the STB-3500, and then plug the AC/DC adapter into a standard
120V 60 Hz AC power outlet.
Once power is applied to the STB-3500, the LED on the STB's front jack panel will light
steadily, indicating that the STB is in standby mode. Also, the display panel will be turned
OFF by the STB as soon as the STB is powered and establishes Television/Display Control
communication with the display.
Note: Once Television/Display Control communication is established between the STB-3500
and the display panel, the STB-3500 will be in control of the display panel, and certain resident
panel functions, like panel buttons, typically will no longer operate.
3. Use the Installer Remote to turn ON the STB/display panel.
While the STB is turning ON and sending the turn ON command to the display, the STB LED
blinks at a constant rate. Once both the STB and the display panel are ON, the STB LED
remains lit but blinks off twice in rapid succession every five seconds. The first image you
should see on the display panel is a prompt to select the video output resolution (see "Setting
the Video Output Resolution" on page 16).
4. Select the video output resolution (i.e., the STB's video output format), and complete the
appropriate Commercial Mode setup procedures, as described in this document.
Note: It is recommended that you complete STB-3500 Commercial Mode setup procedures before
you make external equipment connections to the STB-3500.
8
206-4276

Advertisement

Table of Contents
loading

Table of Contents