Specifications
Environmental specifications
Specification
Temperature range
Operating
Shipping
Maximum wet bulb temperature
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048 m
(10,000 ft) is applicable. No direct sunlight allowed.
2
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Chassis specifications
Specification
Height
Depth
Width
Weight (fully loaded, with three XL450 servers)
Weight, empty
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power Supply on page 49
•
HPE 800W Flex Slot -48VDC Hot-plug Low Halogen Power Supply on page 49
•
HPE 800W Flex Slot Titanium Hot-plug Low Halogen Power Supply on page 51
•
HPE 800W Flex Slot Universal Hot-plug Low Halogen Power Supply on page 51
•
HPE 1400W Flex Slot Platinum Plus Hot-plug Power Supply on page 52
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise website
(http://www.hpe.com/info/proliant/powersupply).
48
Specifications
1
2
Value
10°C to 35°C (50°F to 95°F)
-40°C to 70°C (-40°F to 158°F)
28°C (82.4°F)
10% to 90%
5% to 95%
Value
18.96 cm (7.46 in)
84.91 cm (33.43 in)
44.33 cm (17.45 in)
99.79 kg (220.00 lb)
43.09 kg (95.00 lb)