Summary of Contents for klover PELLET FIRE PLACE 22
Page 1
Pellet insert ENGLISH stove PELLET Main Revision 2.1 FPH_supplement: FIRE PLACE 22 INSTALLATION, USE AND MAINTENANCE, USEFUL TIPS...
Page 3
DoP/KLOVER-010 Identification number : PFP22 Model and/or lot no. and/or serial no. (Art.11-4) : PELLET FIRE PLACE 22 Home heating appliance fed with wood Intended use of the product according to the relevant pellets which can also produce domestic hot...
CONTENTS CONTENTS ..................................1 INTRODUCTION ................................. 3 ........................... 3 MPORTANT SAFETY INSTRUCTIONS ............................4 NSTALLATION EGULATIONS ................................ 4 EALTH AND AFETY THE MACHINE AND THE PELLETS ..........................4 ............................. 4 OMPONENTS OF THE APPLIANCE ..............................6 VERALL DIMENSIONS .............................. 7 ONNECTIONS DATA SHEET .............................
Page 5
EN - Rev. 2.1 Dear Customer, First of all we would like to thank you for choosing a “KLOVER” product and we hope you will be satisfied with this product. Please read the warranty certificate carefully. This is found on the last page of this User Guide. Please contact the authorised Technical Assistance Centre (TAC) for the initial start-up of your stove and to validate the warranty.
- The Klover pellet products are not suitable for use in smokeless zones. KLOVER S.R.L. DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE SPECIFICATIONS OF THIS MANUAL.
Approved Document J. Health and Safety Care must be taken when installing a Klover pellet appliance to ensure that the requirements of the Health and Safety at Work Act are met. Handling Adequate facilities must be available for loading, unloading and site handling the appliance bearing in mind the weight of the appliance.
Page 8
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 RIGHT SIDE TECHNICAL COMPARTMENT Manometer (indicates the pressure of the heating system). Terminal for room thermostat connection. Anti-interference filter connection for power Flue gas outlet. supply cable with 2 built-in fuses (4A 250V).
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Connections data sheet WALL SET-UP REAR VIEW Description of connections M = System delivery (measures hose connections supplied) 3/4" M R = System return (measures hose connections supplied) 3/4" M F = Domestic cold water inlet + system load and boiler body (on prepared models only) (measures 1/2"...
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Pellet properties The appliance has been tested with all types of pellets available on the market. The pellets must have the following properties: - Diameter 6 mm. - Maximum length 35 mm.
Page 13
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 The unit must be installed on a floor with a suitable load capacity. If the existing building does not fulfil this requirement appropriate measures (e.g. load distribution plate) must be taken.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Spaces around and above the appliance The figure below indicates the minimum measurements to be respected when positioning the insert with respect to the walls and/or the two "covering" embrasures (if the latter cannot be easily removed).
Page 15
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Fig. 1 AIR VENT DIAMETER 150mm If it is not possible to put an air vent in the wall behind the appliance, make a hole in a perimeter wall in the room where it is installed and another hole in the covering (see example in Fig.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 The UNI 10683 Standard FORBIDS the drawing of combustion air from garages, warehouses storing combustible materials, or from business premises with a fire hazard. Do not connect the external air vent directly to the appliance through piping. If there are other heating or extraction devices inside the room, the air vents must guarantee a sufficient amount of air for properly operating all the devices.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 - Every direction change must be carried out with a T-shaped fitting and inspection cap. The tubes must be air tight through special seals which resist up to 250° C. Attach the pipes to the wall with special collars to avoid any vibration.
Do not pass electric cables in the immediate vicinity of the flue gas pipe, unless they are insulated with suitable materials. KLOVER srl declines all responsibility for injury to persons and animals or damage to objects due to failure to connect the appliance to earth or to comply with IEC specifications.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Control of a possible three-way motorised valve for the DHW system (on prepared models only) The pellet appliance is equipped as standard with a control for a possible 3-way motorised valve to be installed on the domestic water circuit (for prepared models only).
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Connection to the room thermostat On the back of the appliance there is a bridged terminal which is used to connect the environment thermostat that will command the operation.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 In the event of water with hardness exceeding 28 °f, an anti-limescale device must be installed. This must be selected on the basis of the specific properties of the water.
Page 22
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 The following figure describes the meanings of the status signals appearing on the display left side (1st LED SERIES). ROOM THERMOSTAT: the LED is on when the thermostat contact is open.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 The table explains how the buttons on the display work. DESCRIPTION MODE ACTION Programming mode.. Changes/increases the value of the selected menu item. Increase temperature (1) Working/off.. It increases the temperature of the room/water thermostat.
Page 24
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Menu 02 – Set chrono Sub-menu 02 – 01 – Enable chrono Allows you to globally enable and disable all programmable thermostat functions. For the correct operation it is recommended to enable it (“ON”) when at least one on/off programme (daily, weekly or weekend programme) is...
Page 25
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 PROGRAM 3 MENU LEVEL SELECTION MEANING POSSIBLE VALUES 02 – 03 – 20 START PROG-3 Turn-on time of the third programme Time – OFF 02 – 03 – 21...
Page 26
(detected with KLOVER “Remote control”) is reached..to control the appliance with both the KLOVER “Remote control” room temperature and the boiler thermostat: - enable the room sensor on the “Remote control” (Stove settings menu +> Enable room sensor -> ON) - enable the boiler thermostat contact on the display of the appliance (Menu 4 - Enable contact ->...
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Summary: REMOTE CONTROL MENU 04 – ENABLE R.T. CASE ACTION ROOM SENSOR CONTACT It works with room thermostat contact. It works with room thermostat contact. It works with remote control room sensor only.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 The system and the water inside the boiler can be emptied by opening the “boiler body and system drain cock” situated at the back of the appliance. In intensely cold periods it is good practice to leave the heating system running. In the event of a prolonged absence, anti-freeze must be added to the heating water or the system must be completely emptied.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Working mode During the working phase, by pressing 1, you can set the “SET H2O” (maximum water temperature in the boiler). When this temperature is reached, the appliance enters economy mode operation “T-H2O ECONOMY”.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 - Room Temperature (used only in case of the “Remote control” connection) To modify the ambient temperature, simply select “SET ROOM TEMP” by pressing button 2. Now use buttons 1 and 2.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 What happens if… …the pellets do not ignite If the ignition fails, the display will show the alarm message “NO IGNIT ALLARM”. Cancel the alarm and reset the appliance to standard condition by pressing button 4 for a few seconds.
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Alarm signals The following table describes the different alarms which may appear. DISPLAY VISUALISATION ORIGIN OF ALARM Black-out alarm. When power is cut off under determined conditions (see“What AL 1 - BLACK OUT happens if…”)
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Empty the ash drawer (figure Thoroughly clean the brazier from combustion residues by taking it out from its position and removing any residues inside (figure Use a suitable ash vacuum device to remove any ash deposited under the brazier...
Page 34
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 Remove the two sides of the flue gas pass and clean the combustion chamber well (figures 4 and After having removed the ash drawer, extract the underlying base (right and left)
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 To ensure correct operation, it is necessary to remove the sawdust deposited on the running guides (figure 9) and on the base of the tank (figure 10) at least once every 15 days. The pellet tank must be emptied at the end of every season.
You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are worn or damaged you need to be replace them immediately by contacting a Klover Authorised technical assistance centre.
The following parameters are already stored during the testing of the appliance directly in the factory; these parameters are the result of special tests using several types of pellets and must not be changed without the authorisation of Klover srl so as not to impair the operation of the appliance.
Page 38
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 THRESHOL Pr14 M – 9 – 6 – 14 Flue gas maximum temperature °C 110 – 250 MAXIMUM Flue gas temperature threshold for starting the Pr15 M – 9 – 6 – 15 BLOWER THRESHOL °C...
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1 WIRING DIAGRAM CABLE 4 x 0,75 (OPTIONAL) THREE-WAY CONNECTION LEGEND: FOR MOTORISED THREE-WAY BLUE = COMMON VALVE CONNECTION BLACK = OPENING PHASE BROWN =CLOSING PHASE YELLOW/GREEN = GROUND Earth...
- A copy of the initial start-up report issued by the Authorised Technical Assistance Centre must be preserved along with the proof of purchase receipt. - KLOVER s.r.l. disclaims any liability for accidents resulting from failure to comply with the instructions contained the user and maintenance manual attached to the appliance.
Page 41
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1...
Page 42
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1...
Page 43
PELLET INSERT STOVE PELLET FIRE PLACE 22 EN - Rev. 2.1...
Page 44
Cod. CS.IST.PFP22-EN.FP KLOVER Srl Via A. Volta, 8 37047 San Bonifacio (VR) P.IVA 02324280235 www.klover.it...
Need help?
Do you have a question about the PELLET FIRE PLACE 22 and is the answer not in the manual?