A732-01-880 Issue A
2.2.2
Performance characteristics
Note:
XDS100B is not suitable for prolonged operation at inlet pressures above 20 mbar. Under such conditions,
the inverter may reduce the motor speed.
The above performance curve shows the XDS100B Scroll Booster speed and power consumption when used in
conjuction with a XDS35i backing pump.
2.3
Mechanical data
2.3.1
General
Parameter
Overall dimensions (L x W x H)
Maximum tilt angle
Nominal rotational speed
Mass
Inlet connection
Outlet connection
Degree of protection (IEC60529)
Page 6
Figure 2 - Performance characteristics
1. Speed
2. Power
Table 4 - General mechanical data
Edwards and the Edwards logo are trademarks of Edwards Limited.
XDS100B
476 x 333 x 396 mm
10 degrees
1750 rpm
48 kg
NW40
NW40
IP44