Acyclic Data Exchange; Canopen Eds File - Parker 2003-CB-00 Technical Manual

Canopen– communication option
Hide thumbs Also See for 2003-CB-00:
Table of Contents

Advertisement

8.3 Acyclic Data Exchange

AC20 parameters may be accessed using the SDO (Service Data Object) protocol. The parameter
numbers are mapped to the manufacturer specific range as described in the Manufacturer Specific
Objects section.
Accessing Parameters
The value of a single-element AC20 parameter is accessed by via its corresponding object:
index = 2000h + parameter number
sub-index = 00h
The values of a multi-element AC20 parameter are accessed via its corresponding object:
index = 2000h + parameter number
sub-index = element number + 1
Alternatively, each element has its own parameter number and may be accessed via its corresponding
object index.
A string parameter array must be accessed via each element of the array. Each element has its own
parameter number.
Status Codes
The following CANopen report codes may be reported
CANopen Abort Code
0602 0000h
0609 0011h
0601 0002h
0601 0001h
0607 0012h
0607 0013h
0609 0030h

8.4 CANopen EDS File

AC20 CANopen option is associated with an Electronic Data Sheet (EDS file), which holds a description of
the device and its functions. Most importantly, the file describes the object dictionary implementation in the
module. All the AC20 parameters will be mapped as Manufacturer Specific Objects. EDS files for the AC20
CANopen option may be downloaded from www.parker.com
DOC-0017-06-EN: AC20 Series CANopen Option
Description
Object does not exist in the object dictionary (Parameter does not exist)
Sub-index does not exist
Attempt to write to read-only object
Attempt to read a write-only object
Data type does not match. Too much data.
Data type does not match. Not enough data.
Out of range.
DOC-0017-06-EN-B 04.04.2023
21 (47)