Leak Testing - Fisher & Paykel CG905DW Installation Manual

Table of Contents

Advertisement

Leak testing of the appliance shall be conducted according to the manufacturer's instructions.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system in excess of 3.5mbar.
Maximum inlet gas supply pressure 50 mbar.
After installing the gas supply and making all connections, check thoroughly for possible leaks:
1 Turn all control dials on unit to "OFF" position.
2 Open the valve on the gas supply.
3 Using a leak detection fluid, check each gas connection one at a time by spraying or brushing the solution over
the connection. The presence of bubbles will indicate a leak.
4 If necessary, tighten the fitting and recheck for leaks.
5 Turn on burner valve and light each burner.
6 Check for a clear blue flame without yellow tipping. If burners show any abnormalities, check that they are
located properly and in line with the injector.
11
!3

LEAK TESTING

GAS
GAS
ON
ON