Fisher & Paykel CG905DW Installation Manual page 3

Table of Contents

Advertisement

Ventilation requirements
The appliance should be installed in a room or space
with an air supply in accordance with BS 5440:2 2009.
For rooms with a volume of less than 5 m
ventilation through a free area of at least 100 cm
be required.
For rooms with a volume between 5 m
permanent ventilation through a free area of at least
50 cm
2
will be required, unless the room has a door
which opens directly to the outside air, in which case no
permanent ventilation is required.
For rooms with a volume greater than
10 m
3
, no permanent ventilation is required.
IMPORTANT!
Regardless of room size, all rooms containing the
appliance must have direct access to the outside air
via an openable window or equivalent.
Where there are other fuel-burning appliances in the
same room, BS 5440-2: 2009 should be consulted to
determine the correct amount of free area ventilation
requirements.
The above requirements also allow for use of a gas
oven and grill, but you need to consult a qualified
engineer if there are other gas-burning appliances in
the same room.
1
SAFETY AND WARNINGS
3
, permanent
2
will
3
and 10 m
3
,
Before you install the appliance, please make sure that
the local distribution conditions (nature of gas and
pressure) and the adjustment of the appliance are
compatible. For adjustment conditions for this
appliance see 'Gas rate summary'.
a suitable disconnection switch is incorporated in the
permanent wiring, mounted and positioned to comply
with the local wiring rules and regulations. A means
of disconnection with at least a 3 mm air gap contact
separation in all poles must be incorporated into the
fixed wiring in accordance with the wiring rules, unless
the local wiring rules allow for alternative means.
the appliance is connected to a 220V - 240V 50Hz (10
A) power supply only and earthed via the power supply
cable.
there is a power outlet within reach of the power supply
cable (900 mm from the centre rear of the product).
This must be accessible after installation. The power
supply cable should not touch any metal parts.
If the power supply cable is damaged, it is replaced only
by the special cable: Part no. 534906 TRMNL BLOCK-
FLEX ASY HITEMP UK, obtainable from authorised
Fisher & Paykel Service Agents.
the supply connection point (gas shut-off valve) is
accessible after installation.
the benchtop is made of a heat resistant material.
the installation complies with all the requirements of all
current local codes and regulations.
2