4.4.5
CASE DISASSEMBLY (C.A.I.-C.S.I. Version)
OPERATION SEQUENCE
5
• Disconnect the boiler from the electricity
supply
• Turn off the gas tap
5.1 Unscrew the screws (1) holding the control
panel-case
5.2 Turn the control panel forward to stop
5.3 Unscrew the screws (2) holding the case
-
5.4 Pull the bottom of the case forward and
upward to free it from the framework
Work the other way round from the above for reassembly operations.
! !
MAKE FUNCTIONAL TESTS PAGES 65, 66 and 67.
! !
N. 2 screws
Front panel
2 screws
Case
2
caldaie
ITEM INVOLVED
WITH OPERATION
1
TOOLS NEEDED FOR
THE OPERATION
Magnetic PH2 screwdriver
No tools – by hand
Magnetic PH2 screwdriver
No tools – by hand
25