No.
Component
8
Interface P.C. board
Procedure
WARNING
Do not detach the inverter for 5 minutes after
turning off the breaker as doing so may cause
electric shocks.
1. Detachment
1)Remove the Front panel, Upper panel, Side panel,
Discharge cabinet, Interface P.C board
attachment plate. [Step.1 - Step.4]
2)Remove the support hooks (8 positions) which fix
the board and remove the interface P.C board.
(Fig. 8-1)
2. Attachment
1) Install it in the reverse of the procedure to
remove it.
Support hooks
(8 positions)
Interface
P.C. board