Summary of Contents for PCE Instruments PCE-T 260-ICA
Page 1
+ Type k Temp., Pt 1000 ohm Temp. IR Temp . PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13 Suite 8 Southpoint Business Park TACHOMETER / Jupiter Ensign way FL-33458 Hampshire / Southampton United Kingdom, SO31 4RF...
Page 2
TABLE OF CONTENTS 1. FEATURES......................2. SPECIFICATIONS....................3. FRONT PANEL DESCRIPTION................3-1 Display ......................3-2 Power button......................3-3 HOLD/▲ button...................... 3-4 REC/DOUBLE button..................... 3-5 UNIT/▼ button......................3-6 Function button....................... 3-7 RPM Adapter......................3-8 Surface Speed Test Wheel..................3-9 Funnel type rubber for RPM adapter..............3-10 RS-232 Output Terminal..................
Page 3
1. FEATURES Multi-functions, one instrument combine Photo Tachometer ( RPM ) & Contact Tachometer ( RPM, m/min., ft/min.,in/min. ). Stroboscope , Type K Thermometer, Pt 1000 Thermometer, IR Thermometer . High intensity white light beam for photo tachometer, safety and save the power energy. Wide measuring range from 0.5 to 99,999 RPM.
2. SPECIFICATIONS 2-1 General Specifications 43 mm x 33 mm LCD, 5 digits. Display 5 digits with display unit. Measurement 1. Photo Tachometer. 2. Contact Tachometer 3. Stroboscope Tachometer. 4. Type K thermometer 5. P t 1000 Ω thermometer. 6. IR thermometer Operating Humidity Max.
4. PHOTO TACHOMETER MEASURING PROCEDURE 1) Power On the meter by short pressing the " Power button " ( 3-2, Fig. 1 ) >1.5 seconds , the LCD will light. 2) Press the " Function button " ( 3-6, Fig. 1 ) (short push) in sequence until to the "...
5. CONTACT TACHOMETER MEASURING PROCEDURE 5-1 RPM measurement 1) Power On the meter by short pressing the " Power button " ( 3-2, Fig. 1 ) >1.5 seconds, the LCD will light. 2) Press the " Function button " ( 3-6, Fig. 1 ) (short push) in sequence until to the "...
Page 11
6 STROBOSCOPE OPERATION PROCEDURES 6-1 STROBOSCOPE OPERATION 1) Power On the meter by short pressing the " Power button " ( 3-2, Fig. 1 ) >1.5 seconds , the LCD will light. 2) Press the " Function button " ( 3-6, Fig. 1 ) (short push) in sequence until to the "...
* If press the button once, the display value will change with high resolution ( change just with 1 digit ). * If press the button continuously, the display value will change with low resolution ( change with more digits ). When checking the speed, care must be taken to ensure that the strobe is flashing in unison (one to one) with the object being monitored.
8. RTD Temperature MEASURING PROCEDURE 1) Power On the meter by short pressing the " Power button " ( 3-2, Fig. 1 ) >1.5 seconds, the LCD will light. 2) Press the " Function button " ( 3-6, Fig. 1 ) (short push) , in sequence until to the "...
10. RECORD OPERATION PROCEDURE Data Record ( Max., Min. reading ) 1) The data record function records the maximum and minimum readings. Press the " REC Button " ( 3-4, Fig.1 ) once to start the Data Record function and there will be a " REC "Symbol indicator " will be light.
11. ADVANCED SETTING press the " FUNCTION (SET) Button " ( 3-6, Fig. 1 ) continuously at least Five seconds will enter the " Advanced Setting " mode. then press the " FUNCTION (SET) Button " ( 3-6, Fig. 1 ) once a while in sequence to select the two main function, the display will show : POFF..
12. BATTERY REPLACEMENT 1) When the left corner of " Lobattery symbol " indicator is light, it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate.
Page 17
The 16 digits data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status : Start Word D12, D11 Annunciator for Display ft/min = 11 inch/min = 28...