PCE Instruments PCE-T 260-ICA Operation Manual page 11

Tachometer / stroboscope
Table of Contents

Advertisement

6 STROBOSCOPE OPERATION PROCEDURES
6-1 STROBOSCOPE OPERATION
1) Power On the meter by short pressing the " Power
button " ( 3-2, Fig. 1 ) >1.5 seconds , the LCD will light.
2) Press the " Function button " ( 3-6, Fig. 1 ) (short push) in
sequence until to the " SCOPE RPM " function be
selected, in the same time the " Stroboscope flash light (red)
indicator " (3-17, Fig. 1 ) will be Light.
3) The display will show " last measurement value " RPM ( FPM ),
last measurement value ,memo in the internal memory divice.
Use the " x 2 button(▲ button) " or " / 2 button(▼ button) " to adjust the
display value near the estimate setting signal's RPM
approximately.
*
Press and hold the " DOUBLE button " then Press "
once will double the display value.
For example, the display is " 100.0 " , Press and hold the
" DOUBLE button " then Press "
change to " 200.0 ". Operation again, the display will change to "
400.0 ".....
*
Press and hold the " DOUBLE button " then Press "
once will divide the display value by two.
For example, the display is " 400.0 ", Press and hold the
" DOUBLE button " then Press "
will change to " 200.0 ". Operation again, the display will change
to " 100.0 ".....
6-2 Checking Speed (RPM/FPM)
1) Use the " ▲+ button " ( 3-3, Fig. 1 ) , " ▼- button " ( 3-5,
Fig. 1 ) to adjust the exact display value.
* Press the " ▲+ button " once will increase the display value.
* Press the "▼ - button " once will decrease the display value.
* Press and hold the " ▲+ button "or "▼ - button " will
fast increase or fast decrease the display value.
button " once, the display will
button " once , the display
9
button "
button "

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pce-t 260

Table of Contents