PCE Instruments PCE-T 260 Operation Manual

PCE Instruments PCE-T 260 Operation Manual

Automotive tester + type k temp, pt 1000 ohm temp, ir temp adapter
Hide thumbs Also See for PCE-T 260:

Advertisement

Quick Links

+ Type k Temp, Pt 1000 ohm Temp,
IR Temp adapter.
Automotive Tester
Model : PCE-T 260
OPERATION MANUAL
Your purchase of this
TACHOMETER/
STROBOSCOPER
Strength Meter
marks a step forward for you
into the eld of
precision measurement.
Although this METER is
a complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.

Advertisement

Table of Contents
loading

Summary of Contents for PCE Instruments PCE-T 260

  • Page 1 + Type k Temp, Pt 1000 ohm Temp, IR Temp adapter. Automotive Tester Model : PCE-T 260 Your purchase of this TACHOMETER/ STROBOSCOPER Strength Meter marks a step forward for you into the eld of precision measurement. Although this METER is...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. FEATURES......................2. SPECIFICATIONS....................3. FRONT PANEL DESCRIPTION................3-1 Display Reflecting mark..................3-2 Power button......................3-3 HOLD/ button...................... ▲ 3-4 REC/DOUBLE button....................3-5 UNIT/ button......................▼ 3-6 Function button....................... 3-7 RPM Adapter......................3-8 Surface Speed Test Wheel..................3-9 Funnel type rubber for RPM adapter...............
  • Page 3: Features

    1. FEATURES * Multi-functions, one instrument combine Photo Tachometer ( RPM ) & Contact Tachometer ( RPM, m/min., ft/min. ). Strobscope , Type K Thermometer, Pt 1000 Thermometer, IR Thermometer . * High intensity white white light beam for photo tachometer, safety and save the power energy.
  • Page 4: Specifications

    2. SPECIFICATIONS 2-1 General Specifications 45 mm x 24 mm LCD, 5 digits. Display 5 digits with display unit. Measurement 1. Photo Tachometer. 2. Contact Tachometer 3. Strobescople Tachometer. 4. Type K/J thermometer 5. p t 1000 Ω thermometer. 6. IR thermometer Operating Humidity Max.
  • Page 5 ℃ ℃ ℃ ℃ 2-2 Electrical Specification ( 23 ±5 Photo Tachometer Measurement Photo Tachometer : & Range 5 to 99,999 RPM. Resolution RPM: 0.1 RPM ( < 1,000 RPM ). 1 RPM ( 1 ,000 RPM ). ≧ Accuracy ±( 0.05% + 1 digit ).
  • Page 6 Strobescople Tachometer Flash adjust 60 to 30,000 RPM/FPM. range * RPM : round per minute. * FPM : flash per minute. Resolution 0.1 RPM : < 1,000 RPM. 1 RPM : 1,000 RPM ≧ Function Digital rotate knob, buttons x 2 button, ÷ 2 button, + button, - button, Accuracy ±(0.05 % + 1d)
  • Page 7 Type K/J thermometer Sensor Resolution Range Accuracy Type Type K -50.0 to 1300.0 ± ( 0.4 % + 0.5 ℃ ℃ ℃ -50.1 to -100.0 ± ( 0.4 % + 1 ℃ ℃ -58.0 to 2372.0 ± ( 0.4 % + 1 ℉...
  • Page 8: Front Panel Description

    3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display Reflecting mark 3-14 Battery Compartment/Cover 3-2 Power button 3-15 Reflecting Mark 3-3 HOLD/ button 3-16 Photo led light beam ▲ 3-4 REC/DOUBLE button 3-17 Stroboscope flash light (red) indicator 3-18 Moniter indicator 3-5 UNIT/ button ▼...
  • Page 9: Photo Tachometer Measuring Procedure

    4. PHOTO TACHOMETER MEASURING PROCEDURE 1) Power On the meter by pressing and hold the " Power button " ( 3-2, Fig. 1 ) >1.5 second , the LCD will light. 2) Press the " Function button " ( 3-5, Fig. 1 ) once in sequence until to the "...
  • Page 10: Contact Tachometer Measuring Procedure

    5. CONTACT TACHOMETER MEASURING PROCEDURE 5-1 RPM measurement 1) Power On the meter by pressing and hold the " Power button " ( 3-2, Fig. 1 ) >1.5 sencnds, the LCD will light. 2) Press the " Function button " ( 3-6, Fig. 1 ) once in sequence until to the "...
  • Page 11: Stroboscope Operation Procedure

    6 STROBOSCOPE OPERATION PROCEDURES 6-1 STROBOSCOPE OPERATION 1) Power On the meter by pressing and hold the " Power button " ( 3-2, Fig. 1 ) >1.5 second , the LCD will light. 2) Press the " Function button " ( 3-5, Fig. 1 ) once in sequence until to the "...
  • Page 12: Type K Thermometer Measuring Procedure

    * If press the button once, the display value will change with high resolution ( change just with 1 digit ). * If press the button continuously, the display value will change with low resolution ( change with more digits ). When checking the speed, care must be taken to ensure that the strobe is flashing in unison (one to one) with the object being monitored.
  • Page 13: Rtd Temperature Measuring Procedure

    8. RTD Temperature MEASURING PROCEDURE 1) Power On the meter by pressing and hold the " Power button " ( 3-2, Fig. 1 ) >1.5 sencnds, the LCD will light. 2) Press the " Function button " ( 3-6, Fig. 1 ) once in sequence until to the "...
  • Page 14: Record Operation Procedure

    10. RECORD OPERATION PROCEDURE Data Record ( Max., Min. reading ) Remark : the function strobscope is except. 1) The data record function records the maximum and minimum readings. Press the " REC Button " ( 3-4, Fig.1 ) once to start the Data Record function and there will be a "...
  • Page 15: Battery Replacement

    11. BATTERY REPLACEMENT 1) When the left corner of " Lobattery text " indicator is light, it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate.
  • Page 16 The 16 digits data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status : Start Word D12, D11 Annunciator for Display ft/min = 11 inch/min = 28...

Table of Contents