Page 1
+ Type k Temp, Pt 1000 ohm Temp, IR Temp adapter. Automotive Tester Model : PCE-T 260 Your purchase of this TACHOMETER/ STROBOSCOPER Strength Meter marks a step forward for you into the eld of precision measurement. Although this METER is...
1. FEATURES * Multi-functions, one instrument combine Photo Tachometer ( RPM ) & Contact Tachometer ( RPM, m/min., ft/min. ). Strobscope , Type K Thermometer, Pt 1000 Thermometer, IR Thermometer . * High intensity white white light beam for photo tachometer, safety and save the power energy.
2. SPECIFICATIONS 2-1 General Specifications 45 mm x 24 mm LCD, 5 digits. Display 5 digits with display unit. Measurement 1. Photo Tachometer. 2. Contact Tachometer 3. Strobescople Tachometer. 4. Type K/J thermometer 5. p t 1000 Ω thermometer. 6. IR thermometer Operating Humidity Max.
4. PHOTO TACHOMETER MEASURING PROCEDURE 1) Power On the meter by pressing and hold the " Power button " ( 3-2, Fig. 1 ) >1.5 second , the LCD will light. 2) Press the " Function button " ( 3-5, Fig. 1 ) once in sequence until to the "...
5. CONTACT TACHOMETER MEASURING PROCEDURE 5-1 RPM measurement 1) Power On the meter by pressing and hold the " Power button " ( 3-2, Fig. 1 ) >1.5 sencnds, the LCD will light. 2) Press the " Function button " ( 3-6, Fig. 1 ) once in sequence until to the "...
6 STROBOSCOPE OPERATION PROCEDURES 6-1 STROBOSCOPE OPERATION 1) Power On the meter by pressing and hold the " Power button " ( 3-2, Fig. 1 ) >1.5 second , the LCD will light. 2) Press the " Function button " ( 3-5, Fig. 1 ) once in sequence until to the "...
* If press the button once, the display value will change with high resolution ( change just with 1 digit ). * If press the button continuously, the display value will change with low resolution ( change with more digits ). When checking the speed, care must be taken to ensure that the strobe is flashing in unison (one to one) with the object being monitored.
8. RTD Temperature MEASURING PROCEDURE 1) Power On the meter by pressing and hold the " Power button " ( 3-2, Fig. 1 ) >1.5 sencnds, the LCD will light. 2) Press the " Function button " ( 3-6, Fig. 1 ) once in sequence until to the "...
10. RECORD OPERATION PROCEDURE Data Record ( Max., Min. reading ) Remark : the function strobscope is except. 1) The data record function records the maximum and minimum readings. Press the " REC Button " ( 3-4, Fig.1 ) once to start the Data Record function and there will be a "...
11. BATTERY REPLACEMENT 1) When the left corner of " Lobattery text " indicator is light, it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate.
Page 16
The 16 digits data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status : Start Word D12, D11 Annunciator for Display ft/min = 11 inch/min = 28...