Kohler 10CCOZ61 Service Manual page 84

Mobile generator sets
Table of Contents

Advertisement

8. Remove the four screws securing the junction box
to the generator using a 3/8-inch wrench or nut
driver. Remove the junction box from the
generator. See Figure 8-6.
1
1. Screw
2. Junction Box
Figure 8-6. Removing the Junction Box
9. Remove the six screws securing the end bracket
panel to the end bracket using a 5/16-inch wrench
or nut driver. Remove the end bracket panel to
expose the exciter. See Figure 8-7.
1. Screw
2. End Bracket Panel
Figure 8-7. Removing the End Bracket Panel
10. Disconnect P6 from J6 and P7 from J7.
TP-5648 8/93
11. Remove the four screws securing the exciter field
2
1. Screw
2. Exciter Field
12. Remove the three screws and spacers securing
2
1
1. Screw
2. Diode Circuit Board
Figure 8-9. Removing the Diode Circuit Board
13. Remove the five screws securing the leads to the
to the end bracket. Carefully remove the exciter
field from the generator. See Figure 8-8.
Figure 8-8. Removing the Exciter Field
the rotating diode circuit board to the rotor
armature. See Figure 8-9.
2
rotating diode circuit board. Carefully separate the
Disassembly/Reassembly 8-3
1
2
1

Advertisement

Table of Contents
loading

Table of Contents