INSTALLER: Please leave these instructions with the homeowner.
HOMEOWNER: Please retain these instructions for future reference.
State or local codes may only allow operation of this unit in a vented application. Check your state and local codes.
All Hargrove vent free room heaters comply with IAS U.S. Requirement 5-95.
The installation must conform with state and local codes or, in absence of local codes, to the National Fuel Gas
Code, ANSI Z223.1
IMPORTANT:
Before installing in a solid fuel-burning fireplace, the chimney flue and firebox must be cleaned of
soot, creosote, ashes, and loose paint by a qualified chimney cleaner.
1. Turn the gas supply to OFF.
2. Turn OFF all electrical power to blower (if applicable) before installing, servicing, or
removing.
3. Clean the fireplace floor, walls, and chimney (if used) of any ashes, soot creosote,
obstruction. This
a chimney sweep.
4. Any outside air ducts and/or ash dumps in the fireplace must be permanently closed at the
time of appliance installation.
5.
A mesh fireplace screen must be in place when the appliance is operating unless other
provision for combustion air are provided, the screen shall have an opening(s) for
introduction of combustion air.
NOTE: Before you proceed, make sure your gas supply is OFF!
Check Gas Type: The gas supply must be the same as stated on the heater's rating plate. If the
gas supply is different, DO NOT INSTALL the heater. Contact your dealer for the correct model.
IMPORTANT: This appliance cannot be used with or converted to a gas other than the type
for which it was equipped at the factory.
WARNING: OPERATION OF THIS APPLIANCE ON GASES FOR WHICH IT IS NOT
EQUIPPED MAY LEAD TO CARBON MONOXIDE POISONING.
This product must be installed by a licensed plumber or gasfitter when installed within the
Commonwealth of Massachusetts.
WARNING: CONNECTING DIRECTLY TO AN UN-REGULATED L.P. TANK CAN CAUSE
AN EXPLOSION.
PREINSTALLATION CHECKLIST

FIREPLACE PREPARATION

will minimize any smell from the fireplace. We recommend cleaning by
This unit complies with 527 CMR 30.00 vent free
appliance requirements for Massachusetts.