NOTE!
Installation and service must be performed by a qualified installer, service agent, or
the gas supplier.
ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY.
READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.
INSTALLER: LEAVE THIS INSTRUCTION MANUAL WITH THE CONSUMER!
Hargrove Manufacturing Corporation uses refractory concrete to create the ceramic logs. Each log is
hand finished to assure the most realistic, detailed logs available. The gas burner system is designed
to simulate wood burning, with a yellow smoky flame. For this reason the gas log set must be burned
only in a vented, non-combustible fireplace with the damper open and the chimney free of any
obstruction or restrictions. The fireplace must be designed and approved to burn wood.
The realistic yellow flame produces soot and carbon monoxide. Under proper conditions the bi-
products will exhaust up the chimney. If fumes or soot are evident in the room when the damper is
open; it indicates that the fireplace draft is defective. Do not operate your gas log set until the
f i r e - p a r t s . c o m
fireplace draft is corrected.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
1.
Do not try to light any appliance.
2.
Do not touch any electrical switch.
3.
Do not use any phone in your
building.
4.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
5.
If
you
cannot
supplier, call the fire department.
WARNING:
If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
INSTALLATION AND OPERATION GUIDE FOR
HARGROVE RADIANT GLOW
MODEL: AKRG5/8RMCNG
reach
your
It is the homeowner's responsibility to
assure their fireplace has an adequate
draft.
RECOMMENDED BURN-IN PERIOD
Hargrove gas logs are made of refractory
materials, which withstand high temperatures.
One characteristic of this material is moisture
retention.
burning the log set for only fifteen minutes
during the first burning. After allowing the logs
to cool for at least one hour, the set can be
burned for any length of time.
gas
Hargrove gas logs carry a limited lifetime
warranty against breakage in the original
fireplace.
labor.
handling after using the set causes breakage.
All accessories and metal parts carry a two-
year limited warranty in the original fireplace.
Hargrove will replace items during this period
for the cost of shipping.
1
For this reason, we recommend
WARRANTY
This warranty does not include
This warranty is void if excessive
Hargrove

Advertisement

loading

Summary of Contents for Hargrove AKRG5/8RMCNG

  • Page 1 READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING. INSTALLER: LEAVE THIS INSTRUCTION MANUAL WITH THE CONSUMER! Hargrove Manufacturing Corporation uses refractory concrete to create the ceramic logs. Each log is hand finished to assure the most realistic, detailed logs available. The gas burner system is designed to simulate wood burning, with a yellow smoky flame.
  • Page 2 4. This appliance must be installed only in a solid fuel-burning fireplace with a working flue and constructed of noncombustible material. Solid fuels cannot be used in a fireplace where a Hargrove gas unit has been installed. 5. A permanent free opening must be provided by either the fireplace chimney or chimney damper to vent flue gas. Any chimney damper must be fixed in such a manner, which will maintain the permanent free opening at all times.
  • Page 3: Top View

    FIREPLACE SIZES Each gas log set requires a minimum clearance for the front opening, height, and minimum depth. To determine the largest set that will fit into a fireplace, the depth and width are the critical dimensions. The following illustration reflects a view directly above the fireplace looking down.
  • Page 4 RADIANT GLOW Parts list ITEM DESCRIPTION 21” SETS 24” SETS 30” SETS PG-25 1. Pedestal Grate PG-16 PG-20 EB-22 2. Ember Burner EB-14 EB-18 HBF-24 3. HVF-Burner HBF-18 HBF-24 MV-PO 4. MV Pilot Control MV-PO MV-PO RSHS-225 4a RSHS Heat Shield RSHS-225 RSHS-225 PGRG30L...
  • Page 5 INSTALLATION INSTRUCTIONS HARGROVE RADIANT GLOW DAMPER STOP (OPTIONAL) DAMPER STOP Attach the damper stop clamp to the fireplace damper blade. Position the clamp to prevent full closure of the fireplace damper blade. (See Figure I) See Table II for Minimum Opening Requirements.
  • Page 6: Log Placement

    INSTALLATION INSTRUCTIONS HARGROVE RADIANT GLOW Page 2 BURNER PAN MEDIA Rockwool Fill the burner pan with silica sand. Sand level should be sloped evenly with the sides of the ember burner. Place 2/3 of the rockwool/embers on top of the sand.
  • Page 7: Limited Warranty

    8. Purchaser or user agrees to hold Hargrove Mfg Corp. harmless from any and all claims by the buyer as a result of injury or damage to an ultimate user or other person caused by the product sold herein by the seller to the buyer, whether the injury or damage results from the assembly, installation, operation, shipment, storage, or manufacture of this product.