This
appliance
is
de-
signed to supplement a
current heating system.
It is not designed to be
used as a primary heat
source.
WARNING:
Improper
service, or maintenance can cause personal injury or property
damage. Refer to this manual. For assistance or for additional
information, consult a qualified installer, service agency or the
gas supplier
.
WARNING: If information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use any phone in your building.
* Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
* If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
HARGROVE
Woodland Glow
Vent Free Room Heater
Operation and Installation Guide
READ AND SAVE THESE INSTRUCTIONS
This appliance operates as an unvented room
heater when fitted to a solid fuel burning
masonry or factory built fireplace with the flue
damper closed. It may also be installed in an
approved unvented fireplace (approved models
listed on page 1 in installation guide).
installation,
adjustments,
-WHAT TO DO IF YOU SMELL GAS
alteration,
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.Solid
fuels shall not be burned in a fireplace where an
unvented room heater is installed.
Natural Gas
and
Propane (LP)
Models
WARNING:
THIS IS AN UNVENTED GAS-
FIRED HEATER.
IT USES AIR (OXYGEN)
FROM
THE
ROOM
IN
WHICH
INSTALLED. PROVISIONS FOR ADEQUATE
COMBUSTION AND VENTILATION AIR MUST
BE PROVIDED.
REFERENCE NATIONAL
FUEL GAS CODE NFPA 54, ANSI Z223.1.
REFER TO PAGE 2 OF THE INSTALLATION
INSTRUCTIONS
.
IT
IS

Advertisement

Table of Contents
loading

Summary of Contents for Hargrove Woodland Glow

  • Page 1 HARGROVE Natural Gas Woodland Glow Propane (LP) Models Vent Free Room Heater Operation and Installation Guide READ AND SAVE THESE INSTRUCTIONS WARNING: This appliance This appliance operates as an unvented room THIS IS AN UNVENTED GAS- signed to supplement a heater when fitted to a solid fuel burning FIRED HEATER.
  • Page 2: Table Of Contents

    CONTENTS PAGE PRE-INSTALLATION REQUIREMENTS ........…...... Approved Fireplace Listings .................... Fireplace Location ......................Combustion & Ventilation Air Requirement Worksheet ..........… INSTALLATION SPECIFICATIONS ..............BTU Ratings & Pressure Requirements ...............… Fireplace Dimensions & Clearances ............…....Minimum Clearances to Combustible Materials ............…..Mantle Clearances ......................INSTALLATION ......................
  • Page 3: Pre-Installation Requirements

    PRE-INSTALLATION REQUIREMENTS To determine the safest and most efficient Approved Fireplace Listings (Vent location for your Vent Free Fireplace, you Free Only) must take into consideration the following This appliance operates as an unvented room heater guidelines: certified under ANSI Z.21.11.2b-1998 when fitted to a masonry or factory built fireplace with the flue damper open 1.
  • Page 4: Combustion & Ventilation Air Requirement Worksheet

    PRE-INSTALLATION REQUIREMENTS Combustion and Ventilation Air Requirement Worksheet (Vent Free only) WARNING: IF THE AREA IN WHICH THE HEATER MAY BE OPERATED IS SMALLER THAN THAT DEFINED AS AN UNCONFINED SPACE OR IF THE BUILDING IS OF UNUSUALLY TIGHT CONSTRUCTION, PROVIDE ADEQUATE COMBUSTION AND VENTILATION AIR BY ONE OF THE METHODS DESCRIBED IN THE NATIONAL FUEL GAS CODE, ANSI Z223.1, SECTION 5.3.
  • Page 5: Installation Specifications

    INSTALLATION SPECIFICATIONS BTU Ratings and Pressure Requirements Log Set 21" Sets 24" - 30" Sets Size Gas Type Natural Propane Natural Propane Max. Heat Input 31,500 BTU/hr. 31,500 BTU/hr. 38,500 BTU/hr. 38,500 BTU/hr. Min. Heat Input 23,625 BTU/hr. 23,625 BTU/hr. 28,875 BTU/hr.
  • Page 6: Minimum Clearances To Combustible Materials

    INSTALLATION SPECIFICATIONS Minimum Clearances to Combustible Materials Refer to Fig.2 for the following dimensions IMPORTANT: To insure a safe installation into a A) Minimum left and right clearance to combustible walls = 15". masonry or factory built fireplace, the following instructions must B) Minimum clearance to combustible ceiling = 42".
  • Page 7: Mantle Clearances

    4. Any outside air ducts and/or ash dumps in the fireplace must be permanently closed at the time of appliance installation. All Hargrove vent free room heaters comply with IAS 5. A mesh fireplace screen must be in place when the U.S. Requirement 5-95.
  • Page 8: Gas Line Hook-Up

    INSTALLATION 2. The incoming gas line may be routed into the fireplace GAS LINE HOOK-UP either from the left or right side. NOTE: Before you proceed, make sure your gas supply 3. Include a manual shutoff valve in the gas supply line so is OFF! the appliance may be disconnected for servicing.
  • Page 9: Gas Pressure Check

    INSTALLATION 2. The pressure should be checked with the heater Gas Pressure Check burner and the control set to high (HI). 3. The pressure is preset and locked to avoid tampering. If the pressure is not as specified in "BTU NOTE: Rating and Pressure Requirements"...
  • Page 10: Log Placement

    INSTALLATION Log Placement Fig. 7 STEP 1 STEP 2 & 3 BACK MIDDLE FRONT BURNER ASSEMBLY STEP 4 COMPLETE SET TOP LOGS DO NOT ALLOW THE FLAMES TO COME IN CONTACT WITH LOGS! PERIODIC CHECK OF THE MAIN BURNER FLAMES SHOULD BE PERFORMED. Pg 8...
  • Page 11: Volcanic Cinder

    INSTALLATION VOLCANIC CINDER INSTALLATION Fig. 8 BURNER SYSTEM VOLCANIC CINDER LIGHTING INSTRUCTION TAGS AND RATING PLATE Volcanic Cinder WARNING: DO NOT pour the Volcanic Cinder on the burner system or around the pilot. The Volcanic Cinder is the large bag of black rock that is supplied in the accessory kit.
  • Page 12: Operation

    OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which is lighted by a WARNING: If you do not follow these spark instructions exactly, a fire or explosion may igniter system. When lighting the pilot, follow these result causing property damage, personal instructions exactly.
  • Page 13: Controlling Heat Output

    OPERATION TO TURN OFF GAS TO APPLIANCE TEMPORARY SHUTDOWN PROCEDURE: To turn off main burner only, depress the knob and turn it Clockwise as far as it will go. Do not force. COMPLETE SHUT-DOWN PROCEDURE: Turn off all electrical power in firebox. Turn gas control knob clockwise to the"OFF"...
  • Page 14: Parts Identification

    PARTS IDENTIFICATION (see drawing on page 13) PART NAME 21" SETS 24"-30" SETS (SUB ASSEMBLY) Natural Gas Propane Gas Natural Gas Propane Gas Pedestal Grate & VFHB-21 VFHB-21 VFHB-24 VFHB-24 Burner Tube Aluminum Connector w/ HSC-14 FRONT HSC-16 FRONT HSC-16 FRONT HSC-14 FRONT BURNER BURNER...
  • Page 15: Assembly Identification

    ASSEMBLY IDENTIFICATION 2 – front 2 - back Pg. 13...
  • Page 16: Trouble-Shooting

    TROUBLE-SHOOTING Hargrove Manufacturing test fires all Vent Free burner systems before shipment. Each test consists of lighting the pilot, checking for proper ignition, and leak testing at each connection. Even though all of these precautions are taken sometimes problems do arise. The following Trouble-Shooting chart lists several problems with their probable cause and remedy.
  • Page 17: Trouble-Shooting

    TROUBLE-SHOOTING OBSERVED PROBLEM POSSIBLE CAUSE REMEDY D. When igniter button is pressed, 1. Gas supply turned off or manual 1. Turn on gas supply or open there is spark at ODS pilot, but no shutoff valve closed. manual shutoff valve. ignition.
  • Page 18: Limited Warranty

    8. Purchaser or user agrees to hold Hargrove Mfg Corp. harmless from any and all claims by the buyer as a result of injury or damage to an ultimate user or other person caused by the product sold herein by the seller to the buyer, whether the injury or damage results from the assembly, installation, operation, shipment, storage, or manufacture of this product.