To Turn Off Gas To Appliance - Hargrove HARETHC24N2C Installation And Operation Manual

Vent free gas logs
Table of Contents

Advertisement

OPERATION
TEMPORARY SHUTDOWN PROCEDURE:
COMPLETE SHUT-DOWN PROCEDURE:
Controlling Heat Output
* The heat output can be controlled by adjusting the
vent free burner control knob.
* Another way to regulate the heat output is to open
the fireplace damper.
If you want:
a. more heat radiated into the room – Keep the
damper completely closed
b. less heat radiated into the room – open the
fireplace damper to varying degrees.
Important Safeguards
1. To avoid personal injury, do not touch hot
surfaces when the appliance is operating. Touch
only the piezo ignitor and control knob.
Hot Surfaces
a. Grate
b. Burner
c. Logs
d. Surfaces above the opening of the
fireplace
2. Although your gas logs are very realistic in
appearance, it is not a real wood-burning fireplace
and must not be used for burning any material.
* To avoid irreparable damage to the appliance or
personal injury, matches, paper, garbage, or any
other material must not be placed or thrown on top of
the logs or into the flames.
Close supervision is necessary when the appliance is
being operated near children.
Avoid any drafts that alter burner patterns. Do not
allow fans to blow directly into the fireplace. Ceiling
fans may create drafts that alter burner flame
patterns. Sooting and improper burning will occur.

TO TURN OFF GAS TO APPLIANCE

To turn off main burner only, depress the knob and turn it
clockwise
Turn off all electrical power in firebox. Turn gas control
knob clockwise to the "OFF" position.
Cleaning And Servicing
as far as it will go. Do not force.
Installation and repair should be done by a qualified
service person. The appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding, and material, etc.
It is imperative that control components, burners and
circulating air passageways of the appliance be kept
clean.
If the flames show any unusual shapes or
behavior, or the burners fail to ignite
properly, then the burner holes may require
cleaning.
WARNING:
TURN OFF VENT FREE BURNER
SYSTEM AND ALLOW TO COOL BEFORE CLEANING
OR SERVICING.
MONTHLY CLEANING
1.
If removing logs, when reinstalling, refer to "Log
Assembly Diagram" for correct log placement.
2.
Do not use cleaning fluids to clean logs or any part of
the heater.
3.
Brush logs with a soft bristle brush or vacuum with
brush attachment.
4.
Vacuum loose particles and dust from the front and
rear burner ports, gas control, piezo cover, and grate.
5.
Inspect and clean ODS pilot for operation and
accumulation of lint at air intake holes.
6.
Verify flame pattern and log placement for proper
operation.
7.
Verify smooth and responsive ignition of main burner
and rear burner. Refer to page
pictorial sketch of proper operation.
ANNUAL CLEANING AND INSPECTION
1.
Dealer or qualified inspector – follow the above steps
for proper servicing and inspection.
for proper
17

Advertisement

Table of Contents
loading

Table of Contents