Btu Ratings And Pressure Requirements; Fireplace Dimensions And Clearances - Hargrove HARETHC24N2C Installation And Operation Manual

Vent free gas logs
Table of Contents

Advertisement

BTU RATINGS AND PRESSURE REQUIREMENTS

LOG SET SIZE
GAS TYPE
MAX. HEAT INPUT
MIN. HEAT INPUT
GAS INLET PRESSURE
MAX.
MIN.
REGULATOR PRESSURE
When operating the main burner, use the control knob to raise and lower the min. and max. heat
output. Turn the control knob counterclockwise for max. heat and clockwise for min heat.
Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations
above 2,000 feet, input ratings should be reduced 4% for each 1,000 feet above sea level. Refer
to the National Fuel Gas Code.
WARNING: OPERATION OF THIS APPLIANCE ON GASES FOR WHICH IT IS NOT
EQUIPPED MAY LEAD TO CARBON MONOXIDE POISONING.
Refer to the following charts to determine the proper size set for your fireplace.
Depth
Front Width
PREINSTALLATION SPECIFICATIONS
Natural
30,000 BTU/Hr. 27,000 BTU/Hr.
21,000 BTU/Hr. 20,000 BTU/Hr.
10.5 ins. WC
5 ins. WC
4 ins. WC

FIREPLACE DIMENSIONS AND CLEARANCES

18" SETS
Propane
Natural
35,000 BTU/Hr. 31,000 BTU/Hr.
25,000 BTU/Hr. 23,000 BTU/Hr.
13 ins. WC
10.5 ins. WC
11ins. WC
5 ins. WC
4 ins. WC
10 ins. WC
Log Set
Size
18"
24"
30"
The chart above indicates the minimum
fireplace dimensions for each log set.
24"-30" SETS
Propane
13 ins. WC
11 ins. WC
10 ins. WC
Fireplace Dimensions
Depth
Height
12"
16"
12"
16"
12"
16"
Front
Width
28"
32"
36"