Voltage Conversion; Extension Cords; Adjustments; Tools Required For Adjustments - Baileigh Industrial BHVBS-712B Operating Instructions And Parts Manual

Horizontal-vertical band saw
Table of Contents

Advertisement

Figure 7-1: Grounding
When operated at 230-volt, this tool is intended for
use on a circuit that has an outlet that looks like the
one illustrated in D, Figure 7-1. The tool has a
grounding plug that looks like the plug illustrated in
D. Make sure the tool is connected to an outlet
having the same configuration as the plug. No
adapter is available or should be used with this tool.
If the tool must be reconnected for use on a different
type of electric circuit, the reconnection should be
made by qualified service personnel; and after
reconnection, the tool should comply with all local
codes and ordinances.

7.2 Voltage Conversion

Conversion from 115V to 230V must be done by
a qualified electrician.
The Band Saw is prewired for 115 volts. To change
incoming leads for 230 volts operation:
1) Open main motor junction box cover, and
change leads based on wiring diagram inside
cover. This diagram is also shown in Figure 7-
2. (NOTE: In case of discrepancy, diagram
inside junction box cover takes precedence.).
Reinstall cover.
2) Remove pump motor junction box cover, and
change incoming leads for coolant pump, based
on diagram shown in Figure 7-3. Reinstall
cover.
3) The plug on the end of the power cord must be
replaced with a UL/CSA listed plug rated for 230
volts operation.
Figure 7-2: Main Motor Wiring
Figure 7-3: coolant pump wiring

7.3 Extension Cords

The use of extension cords is discouraged; try to
position machines near the power source. If an
extension cord is necessary, make sure it is in good
condition. When using an extension cord, be sure to
use one heavy enough to carry the current your
product will draw. An undersized cord will cause a
drop in line voltage resulting in loss of power and
overheating.
Table 1 shows correct size to use depending on
cord length and nameplate ampere rating. If in
doubt, use the next heavier gauge. The smaller the
gauge number, the heavier the cord.
Ampere
Rating
Not
More
More
Than
Than
00
06
06
10
10
12
12
16
Table 1: Extension Cord Recommendations

8.0 Adjustments

from power source before making adjustments,
unless indicated otherwise.

8.1 Tools Required for Adjustments

(all may not be needed depending on adjustment)
#2 cross point screwdriver
Wrenches, 10/12/14mm
Hex keys, 3/4/6mm
Square
Straight edge
Clamp

8.2 Vertical Bow Position

1) Disconnect band saw from power source.
2) Rotate stop bracket (A, Figure 8-1) and hold it
out of the way, while lifting bow to upright
position. Pinch point – use caution!
11
Total length of
Volts
cord in feet
120
25
50
100
240
50
100
200
AWG
18
16
16
18
16
14
16
16
14
Not
14
12
Recommended
Always disconnect band saw
150
300
14
12
12

Advertisement

Table of Contents