Zimmer MATCH LWR50F Installation And Operating Instructions Manual

Zimmer MATCH LWR50F Installation And Operating Instructions Manual

Robot module
Table of Contents

Advertisement

Quick Links

INSTALLATION AND
OPERATING
INSTRUCTIONS
MATCH robot module
LWR50F
DDOC01074
THE KNOW-HOW FACTORY
www.zimmer-group.com

Advertisement

Table of Contents
loading

Summary of Contents for Zimmer MATCH LWR50F

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS MATCH robot module LWR50F DDOC01074 THE KNOW-HOW FACTORY www.zimmer-group.com...
  • Page 3: Table Of Contents

    10.2.18 Mounting LWR50F-16-01-A ....................................25 10.2.19 Mounting LWR50F-17-01-A ....................................25 10.2.20 Mounting LWR50F-17-04-A and LWR50F-17-05-A ............................26 10.2.21 Mounting LWR50F-18-01-A and LWR50F-01-02-A-01 ............................26 10.2.22 Mounting LWR50F-20-01-A ....................................26 10.2.23 Mounting LWR50F-21-01-A ....................................27 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 4 12 Maintenance ....................................29 13 Decommissioning/disposal ..............................29 14 RoHS declaration ..................................30 15 REACH declaration ..................................30 16 Declaration of Incorporation ..............................31 17 Declaration of Conformity ................................. 32 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 5: Supporting Documents

    Ö The warning symbols are assigned according to the type of danger. NOTICE General notices contain usage tips and valuable information, but no warnings of dangers to health. INFORMATION This category contains useful tips for handling the product efficiently. Failure to observe these tips will not result in damage to the product. This information does not include any information relevant to health or workplace safety. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 6: Safety Notices

    • Use of the product under extreme conditions, such as aggressive fluids or abrasive dusts • Additional drilled holes or threads Ö Zimmer GmbH shall accept no liability for any damage caused by improper use. The operator bears sole responsibility. ► Make sure that the power supply is disconnected before you mount, adjust, modify, maintain or repair the product.
  • Page 7: Proper Use

    ► Operate the product only when it is in a technical condition that corresponds to the guaranteed parameters and operating conditions. Ö Zimmer GmbH shall accept no liability for any damage caused by improper use. The operator bears sole responsibility.
  • Page 8: Personnel Qualification

    4.3 Instructed personnel Instructed personnel have been trained by the operating company on the tasks and possible dangers of improper behavior. 4.4 Service personnel Service personnel are able to perform the assigned work and can recognize and avoid possible dangers due to their technical training, knowledge and experience. 4.5 Additional qualifications Persons who work with the product must be familiar with the valid safety regulations and laws as well as the standards, guidelines and laws listed in this document. Personnel who work with the product must have facility-issued authorization to commission, program, configure, operate, maintain and also decommission this product. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 9: Product Description

    The product is a safe quick-change system (MATCH robot module). The basic and proven safety principles from EN ISO 13849-1 can be complied with only if original parts from Zimmer GmbH are used. The original parts from Zimmer GmbH required for the safety principles are: MATCH robot module (LWR50F-xx) MATCH gripper (LWR50L-xx) MATCH storage station (ALWR1-50-A) (sensors optional) For the overall safety of the function, all three components (MATCH robot module, MATCH gripper, and MATCH storage station) must be taken into account (see "Functional Safety" section).
  • Page 10: Type Plate

    A type plate is attached to the housing of the product. The article number and confirmation number are shown on the type XX-XXXXXX plate. Article number Confirmation number 5.2 Product variants and compatibility INFORMATION ► You can find information about product variants and their compatibility on our website. ► Please contact Customer Service if you have any questions. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 11: Functional Description

    Spring pin contacts Positioning the MATCH gripper Pneumatic feedthrough Connect LED, Freedrive (robot-specific) Locking LED ring (optional) INFORMATION ► For information on the compatible MATCH grippers, refer to our website. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 12: Led Display (Optional)

    No supply voltage Continuous light • No MATCH robot module coupled. No MATCH robot module coupled. Continuous light • One MATCH robot module coupled. One MATCH robot module coupled. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 13: Sensors

    ► Install an adapter plate between the camera and MATCH robot module. MATCH robot module for quick-change system MATCH gripper for quick-change system MATCH storage station Locking Sensor in storage position (MATCH gripper present) Sensor in inspection position (test channel, locking extended) Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 14: Wiring Diagram Sensor System

    ► Turn in the sensors until they emit a signal. ► Coat the sensors with sealing lacquer. Sensor in storage position (MATCH gripper present) Sensor in inspection position (test channel, locking extended) Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 15: Functional Safety

    Technical supplementary safety measures (sensors) provide a high degree of diagnostic coverage. The product can thus be classified into control category 3 in accordance with Chapter 6.2.6 of DIN EN ISO 13849-1. According to Figure 5, Chapter 4.5.4 of the specified standard, the PL d can be achieved with this product. Fault elimination in accordance with DIN EN ISO 13849-2, Annex A, Table A2 and A3 for the helical compression springs used can be given. 7 Technical data INFORMATION ► You can find the information in the technical data sheet on our website. This data varies within the series, depending on the specific design. ► Please contact Customer Service if you have any questions. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 16: Accessories/Scope Of Delivery

    8 Accessories/scope of delivery INFORMATION If any accessories not sold or authorized by Zimmer GmbH are used, the function of the product cannot be guaranteed. Zimmer GmbH accessories are specifically tailored to the individual products. ► For optional accessories and those included in the scope of delivery, refer to our website.
  • Page 17: Installation

    • The mounting screws are not included in the scope of delivery. • Strength class of the mounting screws is at least 8.8 (DIN EN ISO 4762) ► Observe the tightening torque of the mounting screws. ► Verify the permitted load capacity of the required screw connections in accordance with VDI 2230. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 18: Installing The Product

    10.1 Installing the product ► Insert the product into the robot arm by the connection. ► Loosely attach the mounting screws. ► Tighten the mounting screws crosswise. Connection Mounting screw Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 19: Installing The Energy Supply

    ► Avoid the danger zone. NOTICE The cables that are used by Zimmer GmbH feature a minimum bending radius of 10 x the outer diameter. This bending radius must not be undershot! ► Freely suspended cables must be secured to prevent excessive motion loads or pinching.
  • Page 20: Mounting Lwr50F-00-01-A

    Freedrive signal can be evaluated. Freedrive signal: 24 V DC, if Freedrive button is pressed. M8, 8-pin Socket/bracket Gray 24 V DC 24 V DC supply voltage Pink Input 1 Inward move command Blue Input 2 Outward move command 0 V DC supply voltage The inputs of the product are configured for NPN outputs of the control system. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 21: Mounting Lwr50F-04-01-A

    Output 2 Inside signal Yellow Input 1 Inward move command M8 8-pin plug Gray Input 2 Outward move command Pink Analog output 0 to 10 V DC output Blue Analog GND 0 V DC supply voltage The inputs of the product are configured for NPN outputs of the control system. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 22: Mounting Lwr50F-07-01-A

    Green Output 2 Inside signal Yellow Output 1 Outside signal Gray 24 V DC 24 V DC supply voltage M8, 8-pin Socket/bracket Pink Input 1 Inward move command Blue Input 2 Outward move command 0 V DC supply voltage The inputs of the product are configured for PNP outputs of the control system. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 23: Mounting Lwr50F-10-01-A

    10.2.14 Mounting LWR50F-13-04-A and LWR50F-13-05-A Activation is done via SCM or a commercially available IO-Link master with Port Class B. Color Function Explanation Brown + 24 V DC sensor Actuator supply voltage Blue GND actuator 0 V DC actuator supply voltage M8, 3-pin Connector/bracket Color Function Explanation Brown + 24 V DC sensor IO-Link communication supply Blue GND sensor 0 V DC sensor supply voltage Black IO-Link communication M8, 4-pin Connector/bracket Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 24: Mounting Lwr50F-14-04-A And Lwr50F-14-05-A

    Input 1 Inward move command Pink Analog output 0 to 10 V DC output Yellow Output 3 Connect signal: 24 V DC if MATCH gripper is coupled. Black Output 1 Outside signal M12, 12-pin Connector straight Gray Output 2 Inside signal The inputs of the product are configured for PNP outputs of the control system. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 25: Mounting Lwr50F-15-04-A And Lwr50F-15-05-A

    Green Output 2 Inside signal Yellow Output 1 Outside signal Gray 24 V DC 24 V DC supply voltage M8, 8-pin Connector/bracket Pink Input 1 Inward move command Blue Input 2 Outward move command 0 V DC supply voltage The inputs of the product are configured for PNP outputs of the control system. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 26: Mounting Lwr50F-17-04-A And Lwr50F-17-05-A

    Outward move command Brown Input 1 Inward move command Green Output 3 Connect signal: 24 V DC if MATCH gripper is coupled. Gray Output 1 Outside signal Pink Output 2 Inside signal Blue 24 V DC 24 V DC supply voltage 0430200801 8-pin Socket 0 V DC supply voltage The inputs of the product are configured for PNP outputs of the control system. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 27: Mounting Lwr50F-21-01-A

    Input 2 Outward move command M12, 12-pin Connector straight Output 1 Outside signal Violet Output 2 Inside signal Gray/pink Analog output 0 to 10 V DC output Red/blue Output 3 Connect signal: 24 V DC if MATCH gripper is coupled. The inputs of the product are configured for PNP outputs of the control system. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 28: Static Charge

    INFORMATION ► Details about activation can be found in the information from the robot manufacturer. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 29: Maintenance

    ► Have maintenance work be performed by Customer Service whenever possible. Ö Dismantling and reassembling the product without authorization may result in complications, as special installation equipment is required in some cases. Zimmer GmbH accepts no liability for any resulting malfunctions or damage. 13 Decommissioning/disposal INFORMATION When the product reaches the end of its operational phase, it can be completely disassembled and disposed of.
  • Page 30: Rohs Declaration

    REACH regulation (“Duty to communicate information on substances in articles”). Michael Hoch Rheinau, Germany, 2021-04-01 Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 31: Declaration Of Incorporation

    Machinery and an EC Declaration of Conformity has been drawn up in accordance with Annex II 1 A. Kurt Ross Rheinau, Germany, 2021-04-01 Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 32: Declaration Of Conformity

    A full list of applied standards can be obtained from the manufacturer. Kurt Ross Rheinau, Germany, 2021-04-01 Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...

Table of Contents