This sign means that ON/OFF power switch is turned OFF. This sign means that ON/OFF power switch is turned ON. This signs represents the connection point of the neutral wire in the installation part. This sign represents AC voltage. DAIHAN Scientific, Rotary Vacuum Evaporator 3/31...
12. It provides test scalability with the use of 5.5 Liter Optional Heating Bath. 13. A customer can be compensated for unexpected accidents according to PL Insurance (Product Liability Insurance of this product. (100 million KRW for each liability for personal injury and property damage) DAIHAN Scientific, Rotary Vacuum Evaporator 4/31...
Limit of liability: 100 million KRW for each liability for personal injury and property damage Covered areas: The whole world (North America excluded) DAIHAN Scientific Co., Ltd Contact Info.: (TEL : 080-008-3000, FAX : 033-737-7575) DAIHAN Scientific, Rotary Vacuum Evaporator 5/31...
Page 6
Front side of exploded view ○ ② ○ ⑦ ○ ⑮ ⑪ ① ⑫ ○ ⑨ ⑥ ③ ○ ⑤ ⑩ ④ ⑬ ⑭ Back side of exploded view ⑧ ○ ○ ○ ○ ○ DAIHAN Scientific, Rotary Vacuum Evaporator 6/31...
(5) Apply vaccum grease on the joint unit of Receiving Flask. Make connection with Ball joint clamp. Fasten the screw on the back of Ball joint clamp for complete fixture. (6) Connect valve connecting tube (inner diameter Ø5) to Capillary valve. DAIHAN Scientific, Rotary Vacuum Evaporator 9/31...
Page 10
(14) Put together Condenser holder with support bar. Fix M4 set screw. (15) Place the Heating Bath controller with power cable in the right side of the main body. Position Bath over Bath controller. (15) DAIHAN Scientific, Rotary Vacuum Evaporator 10/31...
1) When evaporating at vacuum (Can be injected at vacuum state) Valve handle shape Valve handle shape Inlet location Liquid input direction 3) When releasing a vacuum Air input direction Inlet location Valve handle shape DAIHAN Scientific, Rotary Vacuum Evaporator 11/31...
Dimension & Net Weight 510×438×h519(Max. 714)mm, 16kg Electrical Reqts. AC220V, 50/60Hz or AC110V, 60Hz ※ An amount of evaporation can be different depending on a vacuum level, a temperature of bath, and a temperature of coolant. DAIHAN Scientific, Rotary Vacuum Evaporator 12/31...
Any glass components damaged in use is not applied to warrant service. While the product is in continuous operation, a part of it can be hot. Be careful for a burn and wear gloves when handling a specimen. DAIHAN Scientific, Rotary Vacuum Evaporator 13/31...
Page 14
※ All circuits, and electric & mechanical parts and components used for this product are technological assets of DAIHAN Scientific Co., Ltd. The product should be repaired only by the technician(s) in the Technical Support Team of DAIHAN Scientific Co., Ltd. or by the technician(s) approved through the education of DAIHAN Scientific Co., Ltd.
⑥ ⑦ ① ② ③ ⑧ ④ ⑨ ⑤ < Figure 3.2.1> The appearance of Eva-05 Model Name Description Control Unit Rotation speed control & timer setting ① Angle Control Knob Knob for adjusting a flask angle ② Evaporating Flask Flask for evaporation ③...
Pull Check the knob’s position to the end. 3) The weight of the assembled glass parts makes it possible to move suddenly when the knob is pulled out. DAIHAN Scientific, Rotary Vacuum Evaporator 18/31...
Page 19
2) By pushing and releasing mode button and Jog-Dial knob at the same time, it is possible to go to Save Flask Height Mode. However, in Locking mode, Jog-Dial knob does not work. Therefore, it is impossible to go to Save Flask Height Mode. Current Height Set Height DAIHAN Scientific, Rotary Vacuum Evaporator 19/31...
Page 20
Icon is displayed on LCD. The current RPM value is displayed on the top `PV(Present Value)’. 5) If Jog-Dial knob is pushed once in rotation, the rotation process stops. Rotation status Current RPM display Set RPM Rotation direction DAIHAN Scientific, Rotary Vacuum Evaporator 20/31...
Page 21
3) If MODE button is pushed once in Locking Mode, it is possible to go to Set Lift Height Limit Mode. ※ After the product runs with proper set values, it is recommended to use ‘Locking Mode’. DAIHAN Scientific, Rotary Vacuum Evaporator 21/31...
1) When power is ON, the initial screen is in Set Operation Time Mode. 2) If Heating Bath fails to be put on Digital Bath controller, Err 1 is displayed. 3) In Set Timer Mode, PV(Present Value) flickers to be on setting standby. DAIHAN Scientific, Rotary Vacuum Evaporator 22/31...
Page 23
3) The proper use of Delay Timer is to set up a reservation time first and then set up a temperature in order to run at the set temperature automatically after the reservation time. DAIHAN Scientific, Rotary Vacuum Evaporator 23/31...
Page 24
Set Temp Offset Mode. * Set Temp Offset If Mode button keeps being pushed and then Jog-Dial Knob is pushed once in Set Temperature Mode, it is possible to change to Set Temp Offset Mode. DAIHAN Scientific, Rotary Vacuum Evaporator 24/31...
Page 25
In Locking Mode, it is impossible to turn or push Jog-Dial Knob. The current operation status is displayed on LCD. If Mode button is pushed once, it is possible to go to Set Timer Mode. ※ After operation, it is recommended to use Locking Mode for test safety. DAIHAN Scientific, Rotary Vacuum Evaporator 25/31...
Otherwise, a fire may break out. 11. Make sure to not to exceed the maximum load. 12. If a glass component is damaged, wear protective equipment and then dispose of it with safety. DAIHAN Scientific, Rotary Vacuum Evaporator 28/31...
3. Check the load capacity. ※ If something abnormal continues to occur even after the above points are checked, contact your purchase agency or call the service center of the head office at 080-008-3000 to request customer service. DAIHAN Scientific, Rotary Vacuum Evaporator 30/31...
This certification is only for international customers. Item Rotary Vacuum Evaporator Model No. Eva-05 Serial No. Date Customer DAIHAN Scientific Co., Ltd. 326, Sinpyeongseokhwa-ro, jijeong-myeon, Wonj-si, Gangwon-do, Korea TEL: +82-2-967-5235 FAX: +82-2-963 5231 Email: info@daihansci.co.kr -Sci.com www.DAIHAN www.ALL forLAB.com DAIHAN Scientific, Rotary Vacuum Evaporator 31/31...
Page 32
V ENTUR E Compa ny ( )인증 ! 벤처기업 PL Insurance. (제조물 배상책임보험) 사용자 설명서 (Version 1.0.2) Written for Eva-05 Models Rotary Vacuum Evaporator, Vertical-type "Eva-05" Sales & Basic A/S : 판매 및 기본 A/S : Man. 330 (17 Oct. 2019)
Page 33
3.6 기준물질표 .................... 25 4. 제품 관리법 4.1 유지 및 관리 ..................28 4.2 Accessories ..................... 29 4.2 이상 발생 시 처리 ................. 30 5. 제품 보증 5.1 품질 보증 .................... 31 5.2 전국 대리점 ................... 32 DAIHAN Scientific, Rotary Vacuum Evaporator 2/32...
폭 발 위 험 휘발성, 폭발성 화학물질을 사용할 경우 폭발의 위험이 있음을 알립니다. 감전 예방을 위한 접지 표시를 알립니다. ON/OFF 전원 스위치에서 OFF를 나타냅니다. ON/OFF 전원 스위치에서 ON을 나타냅니다. 설치 부 중성선의 접속 포인트를 알립니다. 교류전압을 나타냅니다. DAIHAN Scientific, Rotary Vacuum Evaporator 3/32...
11. 회전 방향을 시계/반시계 방향으로 선택가능하며, 방향 자동 반전 프로그램 기능이 탑재 되어 있습니다. 12. 5.5 Liter Optional Heating Bath를 이용한 실험 확장성을 제공합니다. 13. 본 제품은 제조물 배상책임보험(PL보험)에 의해 불의의 사고 시 보상을 받을 수 있습니다. (대인, 대물 각각 1억원) DAIHAN Scientific, Rotary Vacuum Evaporator 4/32...
Page 39
Viton O ring (Inner diameter Ø26.5mm) Power cable (250V~, 1SQ) 양방향 Power cable (250V~, 1SQ) Vacuum silicon hose (inner diameter Ø8) Allen wrench(2.5mm) Allen wrench(2mm) 본 제품은 조립이 필요한 제품입니다. Operation Manual 1부 포함 DAIHAN Scientific, Rotary Vacuum Evaporator 8/32...
2) 농축액 주입 시 (진공 상태에서 주입가능) 1) 진공 농축 시 밸브 손잡이 모양 밸브 손잡이 모양 주입구 위치 유체 주입 방향 3) 진공 해소 시 기체 주입 방향 주입구 위치 밸브 손잡이 모양 DAIHAN Scientific, Rotary Vacuum Evaporator 11/32...
쇼트의 원인이 됩니다. 동작 중 Condenser 및 Bottle 등 유리제품의 기울기를 조정하지 마십시오 Bath 내부에 폭발성 또는 가연성 화학물질(알코올, 벤젠 및 기타 가연성 용제)을 넣고 동작시키지 마십시오. 사용 중 파손된 유리 구성품은 무상서비스 대상이 아닙니다. DAIHAN Scientific, Rotary Vacuum Evaporator 13/32...
Page 45
습기, 먼지가 많은 곳에 설치하지 마십시오. 과열이나 누전의 원인이 됩니다. (오염등급 2) ※ 이 제품에 사용된 모든 회로 및 전기적/기계적 부품 및 구성들은 ㈜대한과학의 기술적 자산입니다. ㈜대한과학의 기술지원팀 기술자나 ㈜대한과학의 교육을 통해 인정한 기술자 에게 수리를 의뢰하시기 바랍니다. DAIHAN Scientific, Rotary Vacuum Evaporator 14/32...
외부 전면 ⑥ ⑦ ① ② ③ ⑧ ④ ⑨ ⑤ < Figure 3.2.1> The appearance of Eva-05 Model 명칭 설명 ① 조절부 회전 속도 조절 및 타이머 설정 ② 각도 조절 노브 플라스크 각도 조절 손잡이 농축 Flask Evaporating Flask ③...
Page 47
T10AL250V~ 과전류 보호 장치 ④ Heating Bath Inlet Bath 전원 입력 ⑤ 조절기 ② ③ ④ ① ⑥ ⑤ <Figure.3.2.2> Lift controller <Figure.3.2.1> Rotary controller ⑨ ⑧ ⑦ ℃ : 20 <Figure.3.2.2> Bath controller DAIHAN Scientific, Rotary Vacuum Evaporator 16/32...
Pull 잡아야 플라스크의 각도가 고정이 됩니다. 노브의 위치를 마지막까지 확인하여 주시기 바랍니다. 3) 회전부를 단단히 잡은 후 노브를 잡아 당겨 주시기 바랍니다. 조립된 유리 파트의 무게로 인해 노브를 당겼을 때 갑자기 움직일 수 있습니다. DAIHAN Scientific, Rotary Vacuum Evaporator 18/32...
Page 50
1) Default로설정된 ‘Free’, ‘3bL’, ‘5bL’ 모드 외에 사용자가 원하는 최저 높이 제한 설정 시에 사용합니다. 2) 플라스크 높이 저장 모드는 모드버튼과 Jog-Dial knob를 동시에 눌렀다 떼면 진입합니다. 단, Locking 모드에서는 Jog-Dial knob 동작이 무시되므로 진입할 수 없습니다. 현재 높이 설정 높이 DAIHAN Scientific, Rotary Vacuum Evaporator 19/32...
Page 51
4) 설정 완료 후 Jog-Dial knob를 1회 누르면 플라스크의 회전 동작이 시작되며 LCD에 아이콘이 표시되며 상단의 `PV(Present Value) 란에 현재 RPM이 표시됩니다. 5) 회전 동작 중 Jog-Dial knob를 1회 누르면 정지합니다. 회전 상태 현재 RPM 표시 설정 RPM 회전 방향 표시 DAIHAN Scientific, Rotary Vacuum Evaporator 20/32...
Page 52
타이머 동작을 조작할 수 없습니다. 또한 LCD Display와 LED 램프로 현재 동작 중 상태를 나타냅니다. 3) Locking Mode에서 MODE 버튼을 1회 누르면 리프트 높이 제한 설정 모드로 진입합니다. ※ 원하는 Setting 값으로 동작 후에는 ‘Locking Mode’ 사용을 권합니다. DAIHAN Scientific, Rotary Vacuum Evaporator 21/32...
1) 전원 ON 시 초기화면은 동작 타이머 설정 모드 입니다. 2) Heating Bath가 Digital Bath controller에 올려져 있지 않으면 Err 1이 표시됩니다. 3) Timer 설정 모드에서는 PV(Present Value) 값이 깜빡이며 설정 대기 상태를 나타냅니다 DAIHAN Scientific, Rotary Vacuum Evaporator 22/32...
Page 54
3) 지연타이머의 적절한 사용은 예약시간을 먼저 설정하고, 그 후 온도를 설정하여 예약 시간이 지난 후 설정한 온도가 자동으로 동작되도록 하는 것입니다. 4) Display에 “d-tr” 깜빡이며 나타나고, 예약 시간을 값을 Jog-Dial Knob로 설정하고 Knob를 누르면 “d-tr” Display에 고정되면 예약 타이머가 동작됩니다. DAIHAN Scientific, Rotary Vacuum Evaporator 23/32...
Page 55
온도 설정 모드에서 MODE 버튼을 누른 채 Jog-Dial Knob를 1회 누르면 Set Temp Offset 모드로 전환됩니다. 온도보정기능은 사용자가 실험의 기준으로 사용하고 있는 온도계와 Digital bath controller에 표시되는 온도 값을 일치하여 실험해야 하는 경우 보정 값을 설정하여 일정 값을 감하거나 더 할 수 있는 기능입니다. DAIHAN Scientific, Rotary Vacuum Evaporator 24/32...
Page 56
Locking Mode에서는 Jog-Dial Knob로 Turning이나 Push 버튼이 적용되지 않으며, LCD Display로 현재 동작 중 상태를 나타냅니다. MODE 버튼을 1회 누르면 Timer 설정 모드로 진입 합니다. ※ 동작 후 실험의 안전을 위해 Locking Mode 사용을 권장합니다. DAIHAN Scientific, Rotary Vacuum Evaporator 25/32...
10. 제품 청소 시에는 조절기나 제품 상부에 직접적으로 물을 붓거나 액체를 올려 놓지 마십시오. 화제의 원인이 됩니다. 11. 최대 적재량을 넘지 않도록 주의하십시오. 12. 유리 제품의 구성품이 파손되었을 때 보호장비를 착용 후 안전하게 폐기하시기 바랍니다. DAIHAN Scientific, Rotary Vacuum Evaporator 28/32...
1. 전원 연결을 확인 합니다. 회전이 되지 않을 경우 2. 현재 설정되어 있는 RPM을 확인합니다. 3. 적재 용량을 확인합니다. ※ 상기 내용을 확인하여도 이상 증상이 계속될 경우, 구매한 대리점이나 본사 서비스센터 080-008-3000으로 연락하셔서 A/S를 의뢰하시기 바랍니다. DAIHAN Scientific, Rotary Vacuum Evaporator 30/32...
강원도 춘천시 퇴계공단 1길 56-16 033-262-7720 033-262-7729 포항 대한사이언스 (대표 엄청호) 경상북도 포항시 남구 효자로 118번길 46-2 054-275-1018 054-274-1014 (주) 대 한 과 학 ㈜대한과학 Call Center 080-008-3000(본사) 080-008-9009(대전) Call Center 080-008-3000(본사) 080-008-9009(대전) 서울사업소 : 02-967-5235 E-mail: info@daihansci.co.kr DAIHAN Scientific, Rotary Vacuum Evaporator 32/32...
Need help?
Do you have a question about the Eva-05 and is the answer not in the manual?
Questions and answers