Page 1
MaXircu WHR Certifications by - - - ISO 9001 Certified. PL Insurance. User's Manual (Version 1.0.1) Written for MaXircu WHR – 20/50/100 Model "MaXircu WHR-50" Sales & Basic A/S : By the Nearest Official Distributor Man 298 (20 Mar. 2017)
3.2 Name of parts ..................3.3 How to use..................... 4. How to manage product 4.1 Maintenance and management............... 4.2 Measures to take in case of abnormality........... 19 5. Product Assurance 5.1 Quality Assurance ................. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 2/20...
It is the grounding indication to prevent electric shock. Indicates OFF in the ON / OFF power switch. Indicates ON in the ON / OFF power switch. Informs a connection point to the neutral wire. Indicates AC voltage DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 3/20...
6. All models are equipped with easy-to-move Caster to provide convenience to users. 7. This product can be compensated for in case of unreasonable accident by product liability insurance (PL insurance). (insured 100 million won for each person and object) DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 4/20...
9. The main power of the product should be connected separately from the power of the computer equipment. - It is prohibited to use the connection with precision equipment because the voltage fluctuation caused by stopping and operation of the freezer may affect DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 5/20...
Page 6
6. When installing the unit, make sure that the wall outlet is easily accessible. 7. Do not ground to gas pipes, plastic tap water pipes or telephone lines. It may cause electric shock, fire, breakdown or explosion of the device. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 6/20...
DAIHAN-Sci.com or ALL for LAB.com Shopping Mall Product Liability (PL) Insurance Admission DAIHAN Scientific (Co., Ltd.) is a member of Product Liability Insurance (PL Insurance), so that its customers can trust our products, (believe and use its products,) by preparing against the accident which can be occurred during using the products by self- production.
Wear safety protective equipment and wipe off any toxic chemicals or dangerous gases that can harm human skin when those are spilled over the human skin DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 8/20...
Page 9
Please check the safety device before operating the product. If unexpected sound, smell or smog occurs, disconnect the mains plug from the wall outlet and contact the Daihan Scientific Service center. Does not use flammable spray or volatile, flammable chemicals such as lacquers, paints, and the like near the product.
Page 10
※ All circuitry and electrical / mechanical components and configurations used in this product are the technical assets of Daihan Scientific. Please ask a technician at the Daihan technical support team or an engineer approved by Daihan Scientific for repair.
⑪ Discharge valve Control of the discharged heating medium ⑫ Drain valve Discharge heating medium ⑬ Circuit breaker Product overcurrent and short circuit protection ⑭ <Table.3.2.1> Name and description of parts DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 11/20...
Page 12
⑤ Knob Switch Function setting and operation On/Off ⑥ Mode Switch Toggle function setting screen ⑦ Sub Switch Switching to the setting auxiliary screen ⑧ <Table 3.2.2> Controller for "MaXircu WHR" DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 12/20...
-. When the operation of the product starts, the current temperature and remaining time of the timer and the text message, "Running .." alternate to indicate that the product is operating. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 13/20...
Page 14
-. In Temp SV setting standby status of Set Operation mode Knob, press the knob switch briefly once and Timer SV on the LCD will blink and wait for timer setting. Turn the switch DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 14/20...
Page 15
HEATER: ON PUMP: ON COMP: ON MODE < Fig 3.3.6. Set HEATER/PUMP/COMP Operation Mode setting Individual action settings -. In Set Operation mode, press Mode button to go to Pump/Comp operation setting DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 15/20...
Page 16
Turn the knob switch to "COMP: OFF", then press and hold the knob switch for more than 1 second to save the setting and the freezer will not operate. PUMP Timer Heat PUSH PUMP, COMP, HEATER Output ON/OFF Select HEATER: OFF PUMP: ON COMP: OFF MODE < Fig 3.3.9. COMP OFF screen> DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 16/20...
Page 17
-. When injecting the circulating fluid (heating medium), please make sure that the circulating fluid (heating medium) is sufficiently drawn out through the discharge valve so that air does not get into the circulating engine. Circulating fluid (heating medium) Press to open Inject heating medium DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 17/20...
3) Check the operating switch indicator light 4) Make sure that there is no foreign substance in the auxiliary tank. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 18/20...
If the temperature does not drop even if there is no abnormality described above, please ask for A/S. ※ If the symptom persists even after checking the above information, please contact A/S by contacting your dealer. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 19/20...
Page 21
V ENTURE Compa ny( )인증 ! 벤처기업 사용자 설명서 (Version 1.0.1) Written for MaXircu WHR – 20/50/100 Model "MaXircu WHR-50" Sales & Basic A/S : By the Nearest Official Distributors. 판매 및 기본 A/S : ㈜대한과학 전국 대리점. Man 299 (20 Mar. 2017)
Page 22
3.2 각 부의 명칭 ..................3.3 사용법 ....................4. 제품 관리법 4.1 유지 및 관리 ..................4.2 이상 발생 시 처리 ................5. 제품 보증 5.1 품질 보증 ................... 5.2 전국 대리점 ..................DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 2/20...
휘발성, 폭발성 화학물질을 사용할 경우 폭발의 위험이 있음을 알립니다. 감전 예방을 위한 접지 표시를 알립니다. ON/OFF 전원 스위치에서 OFF를 나타냅니다. ON/OFF 전원 스위치에서 ON을 나타냅니다. 설치 부 중성선의 접속 포인트를 알립니다. 교류전압을 나타냅니다. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 3/20...
- 구성 품목은 제품 출고 시 포장박스 내부에 같이 들어 있습니다. 구성품 사진 구성품명 적용 모델 및 구성 개수 MaXircu WHR – 20/50/100 본체 1 Unit Model - Operation Manual 1부 포함 DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 4/20...
하절기에는 2시간 이상) 이 시간은 압축기를 예열시켜 냉매와 윤활유를 분리하여 냉동기 가동 시 OIL Forming 현상을 방지하는데 필요한 시간입니다. 13. 반드시 사용 온도 대역에 맞는 순환액(열매)을 사용하여 주시기 바랍니다. 14. 순환액(열매)을 반드시 정해진 용량만 채워서 사용하여 주시기 바랍니다. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 5/20...
금합니다. 이는 제품의 과열이나 전기적 결함을 일으킬 수 있습니다. (실외 사용 금지) 제품의 안전 장치를 확인한 후 제품을 동작 하시기 바랍니다. 예상치 못한 소리, 냄새, 스모그가 발생하면 벽면 콘센트에서 메인 플러그를 DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 8/20...
Page 29
구멍이 벽이나 물체에 의해 차단되지 않도록 합니다. 이는 화재 및 고장의 원인이 될 수 있습니다. ※ 이 제품에 사용된 모든 회로 및 전기적/기계적 부품 및 구성들은 ㈜대한과학의 기술적 자산입니다. ㈜대한과학의 기술지원팀 기술자나 ㈜대한과학의 교육을 통해 인정한 기술자 에게 수리를 의뢰하시기 바랍니다. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 9/20...
⑪ 주입 밸브 수조에 주입되는 열매액 제어 ⑫ 토출 밸브 토출되는 열매액 제어 ⑬ 드레인 밸브 열매액 배출 ⑭ 누전차단기 제품 과전류 및 누전 보호 <Table.3.2.1> 각 부의 명칭 및 설명 DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 10/20...
Page 31
펌프 동작 여부 표시 각 기능 설정 및 동작 On/Off Knob Switch ⑥ Mode Switch ⑦ 각 기능 설정 화면 전환 Sub Switch ⑧ 설정 보조 화면 전환 <Table 3.2.2> Controller for "MaXircu WHR" DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 11/20...
REF LED, PUMP LED가 점등 됩니다. 순환 펌프는 제품 동작과 동시에 동작 되도록 설정되어 있습니다. -. 제품의 동작이 시작되면 현재 온도 및 타이머의 남은 시간 표시와 “Running….” 문구가 번갈아 나타나면서 제품이 동작 중임을 표시합니다. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 12/20...
Page 33
-. Set Operation mode의 Temp SV 설정 대기 상태에서 Knob 스위치를 짧게 한번 누르면 LCD상의 TimerSV가 깜빡이며 타이머 설정 대기 상태가 됩니다. Knob 스위치를 돌려서 원하는 시간을 맞춘 후 Knob 스위치를 1초 이상 길게 누르면 DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 13/20...
Page 34
< Fig 3.3.6. Set HEATER/PUMP/COMP Operation Mode 설정 화면> 개별 동작 설정 모드 진입 -. Set Operation mode 에서 Mode 버튼을 누르면 Pump/Comp 동작 설정 화면으로 넘어갑니다. -. LCD 상의 “HEATER: ON”에서 ON 깜빡이며 설정 대기 화면을 나타냅니다. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 14/20...
Page 35
“COMP: OFF” 로 맞춘 후 저장하면 냉동기가 동작하지 않습니다. PUMP Timer Heat PUSH PUMP, COMP, HEATER Output ON/OFF Select HEATER: OFF PUMP: ON COMP: OFF MODE < Fig 3.3.9. COMP OFF 화면> DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 15/20...
Page 36
-. 제품 내부에 반드시 순환액(열매)가 적정량 들어있는 상태로 제품을 동작 하십시오 -. 순환액(열매) 주입 시 순환 기관 내에 공기가 차지 않도록 토출 밸브를 통하여 순환액(열매)를 충분히 빼주시기 바랍니다. 순환액(열매) 주입구 눌러서 연다 순환액(열매) 주입 DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 16/20...
3. 기기 주변의 통풍은 괜찮은지 확인합니다. 위와 같은 이상이 없음에도 온도가 잘 떨어지지 않을 경우는 A/S를 의뢰하시기 바랍니다. ※ 상기 내용을 확인하여도 이상 증상이 계속될 경우, 구매한 대리점이나 본사 서비스센터 080-008-3000으로 연락하셔서 A/S를 의뢰하시기 바랍니다. DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 18/20...
포항 대한사이언스 (대표 엄청호) 경상북도 포항시 남구 효자로 118번길 46-2 054-275-1018 054-274-1014 (주) 대 한 과 학 ㈜대한과학 Call Center 080-008-3000(본사) 080-008-9009(대전) Call Center 080-008-3000(본사) 080-008-9009(대전) 서울사업소 : 02-967-5235 E-mail: info@daihansci.co.kr DAIHAN Scientific, Refrigerated Heating External Circulators "MaXircu WHR" 20/20...