E. Quick Programming Features
Call length time out (1-9 minutes), 10 = disabled (factory
set to 11111 = 5 minutes)
Silence time out for disconnect (10-90 seconds), 10 =
disabled (factory set to 1111 = 40 secs)
Talk/listen delay (VOX switching speed) 0.1 - 0.9
seconds (factory set to 111 = 0.3 secs)
Forced hang-up command (used to exit programming
and hang up the E-75)
F. Programming Beeps
If a valid "Feature" is entered, a single beep will be heard and you will have 20 seconds to enter a
"Time" value. If an invalid "Feature" (five or more zeros) or forced hang-up command (four zeros)
is entered, 3 beeps will be heard and the E-75 will hang up. If a valid "Time" is entered 2 beeps will
be heard and you will have 20 seconds to enter your next "Feature". If an invalid "Talk/Listen Delay
Time" is entered (10 or more ones), 3 beeps will be heard and you will have 20 seconds to enter
your next "Feature".
G. Call Length Time Out
This feature selects the maximum length of time that calls can be connected. Programmable in
increments of 1 minute up to a maximum of 9 minutes. To disable the call length time out, program
ten ones in the "Time" value location. With the call length disabled, the E-75 phone must rely on
CPC, busy, silence or return dial tone to hang-up. Use the chart at the right. * Note: The factory
default is 5 minutes.
H. Silence Time Out
This feature selects the length of time that calls will remain connected without voice activity.
Programmable in increments of 10 seconds up to a maximum of 90 seconds. To disable the silence
time out, program ten ones in the "Time" value location. Use the chart at the right. * Note: The
factory default is 40 seconds.
Time
Value
1
11
111
1111
11111
111111
1111111
11111111
111111111
10 OR MORE
I. Talk/Listen Delay (VOX Switching Speed)
This feature selects switching time between talk/ listen modes (VOX switching time). Use the
chart above. * Note: The factory default is .3 sec.
9
Table A
Call length
Time Out
1 min
2 min
3 min
4 min
5 min*
6 min
7 min
8 min
9 min
Disabled
Select
Wait for
feature
beep(s)
0
beep
00
beep
000
beep
0000
3 beeps
Silence
Time Out
10 sec
.20 sec
.30 sec*
.40 sec
50 sec
60 sec
70 sec
80 sec
90 sec
Disabled
Enter Time
Wait for
Value
2 beeps
beep
111...
beep
beep
111...
beep
beep
111...
beep
See Table A
in section G
Talk/Listen
Delay
.1 sec
.2 sec
.3 sec*
.4 sec
.5 sec
.6 sec
.7 sec
.8 sec
.9 sec
Error