Viking E-75 Series Product Manual page 5

Hide thumbs Also See for E-75 Series:
Table of Contents

Advertisement

E. Wiring the E-75 Phone Board
* Gel-Filled
Butt Connectors
(included)
E-75 is not
polarity sensitive
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet
and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
* Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a
maximum insulation of 0.082 inches. Do not strip wires prior to terminating.
** Note: To increase surge protection, loosen the PCB mounting screw labeled
with ring terminal (included) from the mounting screw to Earth Ground (grounding rod, water pipe, etc.) After
fastening ring treminal to PCB mounting screw, bend terminal up to avoid interference with single gang box.
*** Note: Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking K-1900-5 Dialer (DOD
317) or K-1900-30 Multi-Number Dialer (DOD 300).
**** Note: When installing a line powered phone on a low voltage and/or low loop current phone system extension,
a Viking TBB-1B Talk Battery Booster may be required,see DOD 632.
(Ring
connector
VIKING
included)
** Earth
Ground
(optional)
Green
Red
(Tip)
(Ring)
Viking C-200, C-250, C-500 or C-2000B
Entry Phone Controller (not included)
VIKING
©
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7
8 9 1 0 11 12 13
J7-
1
2
3
LED1
LED2
LED3
C
C
-or-
Rear View of the
E-75 Circuit Board
Mounting Plate
*** Optional Viking
K-1900-5 Dialer or
K-1900-30 Multi-
Number Dialer
(not included)
MODEL C-2000B
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
Programmable
MODEL: K-1900-5
Quick Programming Guide
1. Call the phone connected to the dialer.
2. Answer phone. Enter
(Factory set to 845464) Write your
security code below:
3. Enter your spped dial number & #00.
Note: For additional programming see
K-1900-5 Technical Practice.
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
J10-
Viking Electronics, Inc.
J8-
J9-
J11-
1
2
3
1
2
3
1
2
3
1
2
3
Hudson, WI 54016
C
LED4
C
LED5
C
LED6
C
LED7
C
LINE IN
**** C.O. Line
or Analog
PABX/KSU Station
©
(programmed for
Tone Dialer
ringdown)
& security code.
PHONE
To dedicated phone, unused trunk/
line input of a phone system, or
Viking C-1000B Doorbox Controller
(as shown above) and fasten a wire
Viking DLE-200B
Two Way Ringdown
Circuit (not included)
VIKING
RINGDOWN
©
1
2
DLE-200B
RES
BUSY
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-75-bkE-75-bnE-75-ssE-75-wh