Figure 2-6 - Aftercooler Approximate Water Flow - Gardner Denver EBM99M 60 Operating And Service Manual

Electra-saver, electra-saver ii stationary base-mounted compressor
Table of Contents

Advertisement

HP
Model
EAM99D
60
EBM99M
EAM99D
75
EBM99M
EAP99K
100
EBP99K
* Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit
WATER PIPING (Water-Cooled Heat Exchanger Models Only) - On machines equipped with water-
cooled heat exchangers, the water inlet and outlet connections are located in the unit base flange on the
left side of the unit.
It is mandatory that any water cooled unit be installed in a shelter heated to
temperatures above freezing (32° F., 0° C).
The water source should be capable of supplying up to the maximum flow shown in Figure 2-5, Page 18,
and
, page19, at a minimum pressure of 40 psig (2.8 bar); maximum allowable water pressure is
Figure-2-6
150 psig (10.3 bar). The water flow rates shown are approximate and a guide to sizing piping, cooling
tower and other water system equipment.
AFTERCOOLER
Water Temperature to Heat
Exchanger
Gallons/minute
60° F
70° F
80° F
.8
1.0
1.4
1.2
1.5
2.0
1.7
2.1
2.8
warranty.
Figure-2-6 – AFTERCOOLER APPROXIMATE WATER FLOW
C C
A A
U U
C
A
U
13-21-603
Maximum Water
Flow
90° F
Gallons/minute *
2.1
26.0
3.0
26.0
4.1
26.0
T T
I I
O O
N N
T
I
O
N
Page 19
Approximate Water
Pressure Drop @ 90° F
Water Temperature PSI
Less than 1 PSI for any
flow rate shown in the table